Specific Operating Instructions for Fence Controller AG M4
Warning: RISK OF ELECTRIC SHOCK
– read and follow all instructions an
d
SAVE ALL
INSTRUCTIONS
, including general instructions.
1
Output voltage in kV
LCD display with
indicator light
2
Earth voltage in kV
LCD display with
indicator light
3
Fastening holes
4
Earth connection
5
Fence connection
with reduced energy
6
Fence connection
with maximum energy
a.) Installation
Fastening holes (3) are provided for wall mounting. The energizer must be mounted against a vertical,
fireproof wall with the connections at the bottom, see above picture, left part. If installed outdoors, the
energizer must also be protected against rain and direct sunlight.
b.) Functional description of the fence energizer controller
Put energizer into service
WITHOUT
fence system. Random values are shown on the displays and the
indicator lights start flashing green or red. The values are not relevant as long as the fence system is not
connected. The energizer is ready for use.
If after connecting the energizer no values are shown on the displays or the indicator lights do not flash, check
the supply voltage and/or the power cable. If no fault is found, have the energizer checked by a technician.
c.) Functional description of the energizer with
CONNECTED
fence system
Display OK
CHECK IDEAL
Output
voltage
> 3.5 kV
(e.g. 4kV = 4000V) indicator
light flashes green
≤
3.5 kV
indicator light
flashes red
6.0 – 10.0 kV;
indicator light
flashes green
Earth
voltage
< 1.0 kV;
indicator light
flashes green
≥
1.0 kV;
indicator light
flashes red
0.0 kV;
indicator light
flashes green
The energizer can be operated with a
SEPARATE
fence system connected to each fence connection (5 – 6).
If the indicator light flashes faster than once per second, the energizer must be disconnected at once and
checked by a technician before it can be used again.
If both fence outputs are used, the display (1) and the corresponding indicator apply to the reduced energy
output (5).
This equipment carries a limited 3-year warranty in accordance with our Exclusive Limited Warranty; Limitation
of Remedies. Please see the attached
Operating Instruction Manual
for warranty terms and conditions.
SERVICE Addresses:
KENCOVE Farm Fence Inc.; 344 Kendall Lane; Blairsville, PA 15717
1
2
4
3
Mains plug used as ON / OFF!
Connection to
115V ~!
Not suited for use in barns as
cattle trainers!
5
6
10,0
0,5
3
10,0
0,0
Fence not OK; output voltage 3.5 kV
Remedy:
See fault finding in enclosed instruction manual (Figure 2; p.5)
Earth not OK; voltage on earth electrode 1 kV
Remedy:
See fault finding in enclosed instruction manual (Figure 2; p.5)
≤
3,5
≥
1,0