EN
welding panel aCX
– pulsed Tig and MinilOg function with memory
2.
1.
3.
4.
7.
8.
9.
11.
5.
10.
6.
12.
13.
14.
1.
4T-LOG and MINILOG function selections
2.
Search arc 5 – 90 % of welding current
3.
Start-current 80 – 150 %
4.
Minilog-current 10 – 150 % of welding current
5.
Tail arc 5 – 90 % of welding current
6.
Selection for spot, synergetic quick pulse, long pulse and MicroTack
7.
Spot time 0.0 – 10.0 s
8.
Pulse current 10 A – power source max.
9.
Pulse ratio 10 – 70 % of pulse time
10. Frequency 0.2 – 250 Hz DC-TIG, 0.2 – 20 Hz AC-TIG
11. Pause current 10 – 70 % of pulse current
12. MEMORY, memory function
13. Selection of channel in memory function
14. SAVE/memory values
If wanted in SETUP-function you can disable search arc and tail arc functions. Hot Start (Soft
Start)- and Minilog -currents can be disabled by adjusting the values to 100 per cent (the same
as the welding current).
15