background image

EN

3. MiX Tig (mixed current aC/DC-)

With mixed current frequency and balance of alternating current are determined by 

adjustments made for AC-current. Adjust by choosing sections 4. – 5. if needed.

The following QuiCk seTup parameters can be adjusted: 

1. 

AC-time  (AC 10 ... 90 %, factory setting 50 %)

2. 

Cycle time (CYc 0.1 ... 1.0 s, factory setting 0.6 s)

3. 

DC-current (DC(-) 50 ... 150 %, factory setting 100 %)

4. 

Balance (bAL -50 … 0 … +10 %, factory setting –25 %)

5. 

Frequency (FrE 50 … 250 Hz, factory setting 60 Hz)

6. 

Selection of AC waveform, sine or square wave (SinuS/SquArE)

7. 

Hot Start time for the 2T function (H2t  0.1 s…5.0 s, factory setting 1.0 s). Can be seen only on 

the 2T function.

Factory setting is marked with a dot after the numeric value.
Growing DC-current increases penetration but decreases cleaning effect.

4. DC- (or DC+) (direct current)

Hot Start time for the 2T function (H2t  0.1 s…5.0 s, factory setting 1.0 s). Can be seen only on 

the 2T function. You can see recommended diameter for electrode by pressing QUICK SETUP 

-button. Diameter depends on current adjustment.

HF/contact ignition in Tig welding (water fill)

TIG arc can be started either with high frequency (HF) or with contact ignition. HF ignition is 

chosen by pressing the HF CONTACT button to turn on the HF light. 
If you use water-cooled torch you can fill it with water by pressing the HF CONTACT button for 

more than 2 seconds. The display reads ’COOLER’.

welding torch switch 2T function 

Gas flow starts when the torch switch is pressed. Welding starts, and the current will rise to 

the Hot Start current within the up-slope time, remain at that level for the set time (H2t) and 

then change to the welding current. The Hot Start function can be disabled and green panel 

light switches off when the Hot Start current is adjusted to 100 %. The current will then rise 

directly to the welding current level within the up-slope time. Release the torch switch, and 

the current starts to drop, and after the selected down-slope time the arc is broken. After this, 

the shield gas will flow for the time selected.

welding torch switch 4T function

Gas flow starts when the torch switch is pressed. Release the torch switch. The ignition spark 

ignites the arc, and the current will rise to the Hot Start current within the up-slope time. You 

can switch from Hot Start current to welding current with a short press of the torch switch. 

You can disable the Hot Start function by adjusting the Hot Start current to 100 %. The current 

will then rise directly to the welding current level within the up-slope time. 
Press the torch switch down, and the welding continues. Release the torch switch, and the 

current starts to drop and after the selected down-slope time the arc is broken. After this, the 

shield gas will flow for the time selected.

remote control

If you choose to adjust the welding current with a remote control unit you need to connect 

the unit and select the remote control selection button. The PANEL light switches off, and 

you can select the unit (R10, foot pedal control R11F, or torch control). The foot pedal control 

works only in 2T mode. Hold the remote control selection button (LO/HI) down to adjust the 

limits of the remote control’s adjustment range.

adjustment of parameters

To select TIG welding parameters you only need to use two buttons: arrow-left and arrow-

right. Red panel light shows parameter you have chosen. Adjustment is done with the control 

knob. When pressing the RETURN button, adjustment of parameters goes straight to welding 

current. The display shows automatically numeric values and the units of the parameters. 

When you adjust the parameters, you can see the value on the numerical display. After 10 

seconds, the display will return to the welding current.

14

M

ast

er

Tig MLS 3000, 3003 A

CDC / © Kemppi O

y / 1112

Содержание MasterTig MLS 3000 ACDC

Страница 1: ...ing Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation Fran ais Manual de instrucciones Espa ol Instrukcja obs ugi Polski Manual de utiliza o Portugu s Manuale d uso I...

Страница 2: ......

Страница 3: ...Operating manual English MasterTig MLS 3000 3003 ACDC Kemppi Oy 1112...

Страница 4: ...ynergetic Pulsed TIG welding 11 3 1 5 Long Pulsed TIG welding 11 3 1 6 Spot welding function 11 3 1 7 MicroTack function 11 3 1 8 TIG welding with mixed AC DC current MIX 11 3 2 Operation functions 11...

Страница 5: ...r omissions Kemppi reserves the right to change the specification of the product described at any time without prior notice Do not copy record reproduce or transmit the contents of this guide without...

Страница 6: ...ng material is recyclable 2 2 Locating the machine Place the machine on a horizontal stable and clean ground Protect the machine from rain and direct sunshine Check that there is enough space for cool...

Страница 7: ...orforelectrodeholder 6 connector for earth cable Markings for poles on the machine front are embossed Rear of machine 1 Mains switch 2 Snap connector for gas Installing gas cooled torch Installing wat...

Страница 8: ...r electrical devices without special circuits generate harmonic currents into distribution network High rates of harmonic current may cause losses and disturbance to some equipment MasterTig MLS 3000...

Страница 9: ...t 2 Fasten clamp properly so that contact surface is as large as possible 3 Check that clamp is fastened firmly 2 9 Cooling unit to Mastercool 30 nOTE Cooling liquid is injurious Avoid also contact wi...

Страница 10: ...for the cooling unit 1 2 1 Control connector 2 Protective earth nOTE Only an authorised electrician is allowed to install electrical connection See the mounting instructions delivered with the coolin...

Страница 11: ...allation instructions are valid for most gas flow regulator types 1 Stepasideandopenthebottlevalve A forawhiletoblowoutpossibleimpuritiesfromthe bottle valve Note Watch out for the gas flow 2 Turn the...

Страница 12: ...C20 electrodes grey for AC welding The table is only given as a guide Welding current range AC Electrode Gas nozzle Gas flow rate min min maks WC20 mm number mm Argon A A A l min 15 25 90 1 6 4 5 6 6...

Страница 13: ...ferent thicknesses can best be made out by using mixed current Adjust values with SETUP function if needed 3 2 Operation functions 3 2 1 Power source Note Always switch the machine on and off from mai...

Страница 14: ...10 GAS TEST button 11 Control knob for welding parameter adjustment 12 Pre gas 0 0 10 0 s 13 Upslope 0 0 10 0 s 14 Hot Start current 100 150 100 not in use 15 Welding current 16 Downslope 0 0 15 0 s 1...

Страница 15: ...ase material and to the electrode Effect of the balance adjustment A positive balance value breaks up aluminium oxide more effectively but heats the electrode more than the workpiece the tip blunts A...

Страница 16: ...n rise directly to the welding current level within the up slope time Release the torch switch and the current starts to drop and after the selected down slope time the arc is broken After this the sh...

Страница 17: ...icroTack 7 Spot time 0 0 10 0 s 8 Pulse current 10 A power source max 9 Pulse ratio 10 70 of pulse time 10 Frequency 0 2 250 Hz DC TIG 0 2 20 Hz AC TIG 11 Pause current 10 70 of pulse current 12 MEMOR...

Страница 18: ...ot time needed by turning the pulse control knob TIG Micro tack welding function MicroTack You can select the MicroTack function with a long press of the MicroTack arrow button 6 and MicroTack light t...

Страница 19: ...e panel display shows HI Welding is started with a light press on the pedal the arc ignites to the set minimum current Welding current goes to maximum when the pedal is pressed to the bottom The arc i...

Страница 20: ...2 ON TIG the start of remote control scale MMA the end of the scale OFF Remote control as a normal current regulator SearchArc On Off A13 ON SearchArc on OFF SearchArc off Current freeze function A14...

Страница 21: ...circumstances of machine utilisation should be taken into consideration when planning product maintenance Careful use and preventive maintenance help to avoid unnecessary production disturbances and b...

Страница 22: ...irculation Check cooling unit for water circulation clean cooling unit filter and air grate Add cooling liquid if necessary For further information and assistance contact your nearest Kemppi service w...

Страница 23: ...627016016 TTC 220 4 m 627022004 TTC 220 8 m 627022008 TTC 220 16 m 627022016 Gas flow meter AR clock 6265136 Cooling unit Mastercool 30 6163900 Water cooled torches TTC 200W 4 m 627020504 TTC 200W 8 m...

Страница 24: ...range TIG 3 A 10 0V 300 A 22V MMA 10 A 20 5V 250 A 30V Max welding voltage MMA 45V 250 A Open circuit voltage 63V DC VRD 35V DC Idle power TIG 13W MMA 190W Power factor at max current 0 62 Efficiency...

Страница 25: ...5V 250 A 30V Max welding voltage MMA 35 45V 250 A Open circuit voltage 58V DC Idle power TIG 10W MMA 160 180W Power factor at max current 0 95 Efficiency at max current 80 84 77 81 Striking voltage U...

Страница 26: ...g voltage 24V DC Cooling power 1 0 kW Connection capacity 100 ED 50W Maximum pressure 4 0 bar Cooling liquid 20 40 glycol water Tank volume approx 3 l External dimensions LxWxH 500x180x260 mm Weight 8...

Страница 27: ...EN 25 MasterTig MLS 3000 3003 ACDC Kemppi Oy 1112...

Страница 28: ...Tel 33 1 30 90 04 40 Telefax 33 1 30 90 04 45 sales fr kemppi com KEMPPI GmbH Otto Hahn Stra e 14 D 35510 BUTZBACH DEUTSCHLAND Tel 49 6033 88 020 Telefax 49 6033 72 528 sales de kemppi com KEMPPI SP K...

Отзывы: