Err 171: Configuration not found for the device
The equipment’s internal data transmission has been cut off. The optional features cannot be
used. Turn off the machine, detach the welding gun and re-start the machine. If an error code
does not appear in the display, the fault lies in the welding gun. If this error code pertains,
contact maintenance.
Err 172: A wrong configuration code has been supplied
License activation with DataGun has failed. Turn off the machine, detach DataGun and restart
the machine. Reconnect DataGun. If this error code recurs, contact maintenance.
Err 201: Use of PMT gun is prevented
You try to use the PMT welding gun, but the necessary settings have not been entered into
the machine’s control panel. Select ‘PMT gun’ from the control panel SETUP menu, if you wish
to use it. This fault can also occur with other guns, if the trigger contacts are bad or dirty.
Err 221: Two wire feeders connected with the same device address.
Two wire feed units have the same device address. Define different addresses for the devices
as follows:
1.
Press any button on either control panel (except the ESC button). “Add” (Device Address)
is displayed.
2.
Change the device address using the right-hand control knob.
3.
Return to normal status by pressing again any button on the control panel.
The machines will return to normal status within 15 seconds.
Other error codes:
The machine can show codes not listed here. In the event of an unlisted code appearing,
contact an authorised Kemppi service agent and report the error code shown.
4.
DISPOSAL
Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic
equipment, and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and taken to an appropriate
environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional
collection centre, per the instructions of local authorities or a Kemppi representative. By
applying this European Directive you will improve the environment and human health.
5.
ORDERING NUMBERS
FastMig MR 200
MXF 63
6136100
FastMig MR 300
MXF 65, MXF 67
6136200
11