- 68 -
7.3
Troubleshooting
Fault
Possible cause
Note
Not all dust
particles are
collected
Distance between the
extraction hood and the
welding position too great
Move the extraction hood
closer
Clean air outlet obstructed Keep clean air outlet free of
obstruction
Signal horn
sounds
The set minimum
extraction capacity has not
been reached. Filter inserts
saturated,
piping/extraction system
closed off
Filter change required,
check piping/extraction
system, contact service
Requirements are no
longer met!
Extraction
capacity too
low/non-
existent
Filter inserts saturated
Replace filter inserts
Phase error/missing phase
The fan is rotating in the
wrong direction
Changeover of two phases
in the CEE plug by an
electrician
Dust particles
escape on the
clean air side
Filter inserts damaged
Replace filter inserts
Motor
protection
switch trips
Suction filter blocked
(motor temperature too
high)
Allow product to cool down
and/or replace suction filter
Product does
not start.
No mains voltage
Have this checked by a
qualified electrician
Start/stop sensor (optional
fitting) connected but no
current detected
Welding process not yet
started
Start welding process
Tab. 15: Troubleshooting
NOTE
If the fault cannot be corrected by the customer, please contact the
manufacturer’s service department.