30/ 32 – K410068602012-00 / 05.2019 –
©
www.kemper-olpe.de
Example for settings: Flushing potable water systems
Flushing should be undertaken weekdays on Mo, We, Fr and Saturday, each at 8 am for 5
minutes.
Timer01 / Open time: 08:00:00 / Open weekday: Mo _ We_ Fr _ Sa / Close time: 08:05:00 /
Close weekday: Mo _ We_ Fr _ Sa
3.6
Acknowledging the alarm
If there is a backflow, the Free Drain Float
Switch (Figure 688 00) will trigger the alarm
and the controller will close the valve.
After remedying the backflow cause, the val-
ve can be released again via the error ack-
nowledgment.
After acknowledging the control returns to
the previously set operating mode.
Example for settings: Protection during absence for doctor's offices, business,
company buildings, etc.
Weekday Mo - Fr: Cut-off time: 8 pm, Opening time 8 am
Weekend Sa - Su: protected except during cleaning on Sa 10 am – 12 pm
Timer01 / Open time: 08:00:00 / Open weekday: Mo,Tu,We,Th,Fr,_ _ / Close time: 20:00:00
/ Close weekday: Mo,Tu,We,Th,Fr,_ _
Timer02 / Open time: 10:00:00 / Open weekday: _ _ _ _ _ _ Sa / Close time:12:00:00 /
Close weekday: _ _ _ _ _ _ Sa