KEMPER Filter-Master XL Operating Instructions -
EN
- 82 –
Technical changes and errors excepted.
Technical Data
Power supply
see Identification Plate
Motor performance
1.5 kW
Maximum power consumption
See Identification Plate
Duty cycle
100 %
Type of protection
IP 54
ISO Class
F
Perm. ambient temperature
-10 / +40°C
Device capacity, max.
1000 m³/h, with exhaust
arm
Vacuum, max.
2,900 Pa
Filter surface area
10 m
2
Minimum volume flow
(trip level volume flow monitoring)
710 m³/h
Exhaust arm
NW 150, 2 m long
3 m long
4 m long
Welding fume separation class as per
EN ISO 15012-1
W3
Compressed air required:
5 - 6 bar, clean, dry and
free of oil (compressed air
quality, Class 2:4:2
according to ISO 8573-1)
Sound pressure level at a distance of 1 m according
to DIN EN ISO 3744
69 dB(A)
Width
655 mm
Depth
655 mm
Height
1,460 mm
Weight
135 kg