KEMPER Filter-Master XL Operating Instructions -
EN
- 79 –
Technical changes and errors excepted.
9.1 Daily Checks
Check Task
Implementation / measures
Check the connecting hose between the
suction hood and filter unit for fire holes.
Visual inspection, if necessary, the
connection hose must be replaced
(see operating instructions of the
exhaust arm).
Check the connection cable and connector
for damage.
Visual inspection, if necessary, the
connection cable or connector must be
replaced by an authorised electrician.
In the event of a change of location, check
the direction of rotation of the impeller.
See Chapter 6.7
Check the filter insert for a possible "Filter
breakthrough".
Observe the drain valve on the rear of
the filter device
during use for escaping smoke or
heavy dust deposits. This could
indicate a "filter breakthrough"
i.e. welding smoke particles
are only separated inadequately from
the filter insert. Do not operate
The filter device any more in such a
case, since contaminated air
gets into the work environment and
damages the health of
persons.
Check the level of the dust collection
charge.
See Chapter 7.4
Drain the condensate from the compressed
air tank regularly.
See Chapter 7.5