background image

EN

1. Dynamics control

Dynamics function controls the rate of rise of current when the filler wire is in short circuit 

with the welding plate. This control adjustment is necessary due to the alternative welding 

parameters, materials, wire sizes, gas types and current values used.
The welding dynamics scale is –9 to +9. Negative values make the rise of current slower, which 

results in a hotter and more fluid weld characteristic. Positive values make the rise of current 

faster, which results in a colder welding condition. This can result in more spatter during 

welding depending on the filler wire size and type used.

How to find the optimal dynamics setting?

Start by setting ‘0’ and make a test weld after selecting the correct wire feed speed and 

voltage values. Fine tune the welding arc by trying different values in the negative (-) and 

positive (+) sides of the dynamics scale. 

2. Control knob for wire feed speed or power (adaptive mode)

This control knob increases and reduces the speed of filler wire delivery or power to the 

welding arc. The scale is regulated in meters per minute or amperes. There is also a graphical 

display bar indicating the proportion of motor speed or power selected.

3. Control knob for voltage or arc length (adaptive mode)

This control knob increases and reduces the available output voltage of the machine to the 

welding arc. The scale is regulated in volts and is also supported by a graphical display bar that 

indicates the proportion of the available output voltage selected.
In adaptive mode this control knob offers minor arc voltage adjustment for fine tuning the 

welding arc.

4. Timer button for spot welding and cycle arc welding

SPOT /

CYCLE

   

The spot and cycle arc timer offers two modes of function. By pressing and selecting the SPOT 

timer, you regulate the time duration for one single ‘SPOT’ welding cycle from either 0.1 to 9.9 

seconds of arc time. By selecting the ‘CYCLE' arc timer you regulate the machine to a repeating 

cycle of arc time and pause time. The pause time offered is 0.1 to 3 seconds. Select function by 

depressing button 4. Regulation and adjustment of SPOT and CYCLE arc values are adjusted 

by the voltage control (item 3). Function selection is confirmed by either one dot (SPOT TIME) 

or dash line (CYCLE TIME) under the word 'Timer’ in the display.

5. Selection of 2T/4T gun operating mode

2T / 4T

This button offers you two modes of welding gun functions. The selected mode is indicated as 

either 2T or 4T in the display. 

• 

In 2T mode 

the welding arc is started by a single press and hold of the welding gun 

trigger. Welding continues whilst the trigger is held, and stops when the trigger is 

released. 

• 

In 4T mode 

the gun trigger is pressed and gas starts to flow. When the trigger is 

released, the arc ignites. Welding continues unti the trigger is pulled and released for a 

second time. This mode is useful for long welding durations.

23

© Kemppi Oy / 1442    

Содержание 181A

Страница 1: ...MV 323AMV Operating manual Bruksanvisning Gebrauchsanweisung Manual de instrucciones K ytt ohje Manuel d utilisation Manuale d uso Gebruiksaanwijzing Brugsanvisning Instrukcja obs ugi Manual de utiliz...

Страница 2: ......

Страница 3: ...OPERATING MANUAL English...

Страница 4: ...re spool 12 4 3 Setting the spool brake force 12 4 4 Loading the welding wire to feed mechanism 13 4 5 Welding gun 14 4 6 Setting the pressure of the feed rolls 15 4 7 Wire guide tubes and feed rolls...

Страница 5: ...no liability can be accepted for any errors or omissions Kemppi reserves the right to change the specification of the product described at any time without prior notice Do not copy record reproduce or...

Страница 6: ...tion Kempact RA is equipped with a security feature that automatically stops the wire feed and shielding gas flow and cuts the voltage from the wire if the welding gun trigger is held down for more th...

Страница 7: ...the metal chassis of the machine does not come into contact with the welding circuit and or surfaces so connected NOTE Never aim metallic grinding spray sparks towards the equipment 2 3 Distribution...

Страница 8: ...consultation with the distribution network operator if necessary that the equipment is connected only to a supply with a short circuit power Ssc greater than or equal to 1 1 MVA Kempact 323 MVU This...

Страница 9: ...CHINE INTRODUCTION 3 1 General view of the machine FE 32 1 3 5 4 2 1 Supply voltage cable 2 Main switch 3 Shielding gas hose connector 4 Welding gun and cable 5 Earth return clamp and cable 7 Kemppi O...

Страница 10: ...or mains plug may be installed or replaced only by an electrical contractor or installer authorised to perform such operations Welding gun Kempact RA welding machines are supplied with Kemppi FE rang...

Страница 11: ...nector at the back of the machine Connect the other end of the gas hose to the gas cylinder via a suitable and approved single stage regulator valve where outlet flow rates can be adjusted NOTE Never...

Страница 12: ...the machine handles 3 Place one foot to the foot base plate located in front of the air intake grill Press your foot firmly downwards and pull back the machine at the same time so lifting the machine...

Страница 13: ...ithout a gas cylinder loaded in place When transporting the machine between sites welding gas cylinders must be removed from the chassis secured and transported by other means 4 BEFORE YOU START USING...

Страница 14: ...gainst the internal surface of the wire feed unit chassis or door This may result in increased drag impacting on weld quality This may also result in long term wire feed unit damage rendering the unit...

Страница 15: ...exposing about 150 mm of filler wire from the front of the machine 3 Close the top feed roll s lever s over the filler wire and close the pressure arm s 4 Cut away any deformed filler wire section an...

Страница 16: ...er to remove the sharp cut tip of the filler wire before loading the wire to the welding gun so preventing damage to the liner inside the welding gun cable This is particularly important for soft fill...

Страница 17: ...stment knob depending on the Kempact RA used For models fitted with the two roll GT02 wire drive system the more pressure applied the greater the number of graduation marks visible For models fitted w...

Страница 18: ...3 1 0 W007534 1 2 W007535 A C D A C D DuraTorque models 253R 253A 253RMV 253AMV 323R 323A 323RMV 323AMV mm outlet tube middle tube inlet tube wire spiral guide Ss Al Fe Mc Fc plastic 0 6 W007448 W0074...

Страница 19: ...cessary for reliable filler wire drive without deformation of the wire itself For flux cored filler wires select a knurled feed roll to achieve better wire grip NOTE Slight slippage is recommended in...

Страница 20: ...ssure tension arm 2 Lift the upper feed roll on its pivot to the maximum open position 3 Pull out mounting pin of the upper feed pressure roll and replace the roll with a new one 4 Open the locking sc...

Страница 21: ...m 6 Replace the rubber terminal covers The rubber covers must always protect the terminals during use 4 9 1 Dusty work environments If the working environment frequently carries airborne metallic dust...

Страница 22: ...e welding parameters materials wire sizes gas types and current values used The welding dynamics scale is 9 to 9 Negative values make the rise of current slower which results in a hotter and more flui...

Страница 23: ...nction selection is confirmed by either one dot SPOT TIME or dash line CYCLE TIME under the word Timer in the display 6 2T 4T gun switch latching button 2T 4T This button offers you two modes of weldi...

Страница 24: ...ctive 5 2 Adaptive control panel DYNAMICS POWER U W006149 CRATER FILL SPOT CYCLE GAS POST GAS A MATERIAL WIRE 2T 4T MODE HOT SPOT MEMORY SAVE 1 2 3 4 POST GAS mm mm m min A BRAZING r CRATER AUTOMATIC...

Страница 25: ...arc The scale is regulated in volts and is also supported by a graphical display bar that indicates the proportion of the available output voltage selected In adaptive mode this control knob offers mi...

Страница 26: ...visible 9 WireLine service indicator Under normal working conditions the WireLine service indicator is not visible However if the welding gun contact tip or liner becomes dirty and blocked or the wir...

Страница 27: ...me value with adjustment knob 3 The POST GAS adjustment range is from 0 1 second to 3 0 seconds 14 Selection of crater fill function adaptive mode CRATER FILL When operating in adaptive mode and AUTOM...

Страница 28: ...vex flat and concave Select the desired settings and you are ready to weld 5 3 Parameter guides Fe 0 8 mm 5 18 CO Ar PlateThickness mm 0 5 0 8 1 1 5 2 2 5 3 WireFeedSpeed m min 2 2 5 3 5 5 8 10 13 Set...

Страница 29: ...e welding starts Ensure the earth return clamp is connected to the work piece Ensure that you are wearing the correct safety equipment before you start welding including suitable welding clothing the...

Страница 30: ...with the FE 20 25 welding guns only Setting and function 1 Before using HOT SPOT function release the pressure tension arms at the wire feed mechanism 2 Rotate the filler wire spool slowly clockwise r...

Страница 31: ...ding gun wire liner with dry compressed air NOTE When using compressed air pistols ensure you are wearing adequate safety equipment including suitable work clothing gloves and eye protection Never dir...

Страница 32: ...ctly adjusted Check gun liner is not blocked Replace if necessary Check correct gun liner is fitted for the filler wire size and type Check contact tip for size type and wear Check gun is not over hea...

Страница 33: ...s of local authorities or a Kemppi representative By applying this European Directive you will improve the environment and human health 8 ERROR CODES Error 2 Mains under voltage The machine has detect...

Страница 34: ...FE 32 5m P2222 Kempact 251A FE25 3 5m P2205 Kempact 251A FE25 5m P2206 Kempact 253A FE32 3 5m P2209 Kempact 253A FE32 5m P2210 Kempact 323A FE32 3 5m P2214 Kempact 323A FE32 5m P2215 Welding guns FE...

Страница 35: ...djustment range 1 0 14 0 m min 1 0 18 0 m min Voltage adjustment range 8 0 26 0V 8 0 29 0V Filler wires Fe solid 0 8 1 2 mm 0 8 1 2 mm Fe cored wires 0 8 1 2 mm 0 8 1 2 mm Ss 0 8 1 2 mm 0 8 1 2 mm Al...

Страница 36: ...1 0 18 0 m min 1 0 20 0 m min Voltage adjustment range 8 0 31 0V 8 0 32 5V Filler wires Fe solid 0 8 1 2 mm 0 8 1 2 mm Fe cored wires 0 8 1 2 mm 0 8 1 2 mm Ss 0 8 1 2 mm 0 8 1 2 mm Al 1 0 1 2 mm 1 0...

Страница 37: ...V 20A 31V 250A 10V 20A 32 5V 320A No load voltage 46V 50V Idle power 35W 35W Power factor at max 250A 26 5V 230V 0 94 320A 30V 230V 0 94 250A 26 5V 400V 0 93 320A 30V 400V 0 94 Efficiency at 100 ED 15...

Страница 38: ...Operating temperature range 20 40 C 20 40 C Storage temperature range 40 60 C 40 60 C Standards IEC 60974 1 IEC 60974 1 IEC 60974 5 IEC 60974 5 IEC 60974 10 IEC 60974 10...

Страница 39: ......

Страница 40: ...l 33 1 30 90 04 40 Telefax 33 1 30 90 04 45 sales fr kemppi com KEMPPI GmbH Perchstetten 10 D 35428 LANGG NS DEUTSCHLAND Tel 49 6 403 7792 0 Telefax 49 6 403 779 79 74 sales de kemppi com KEMPPI SP KA...

Отзывы: