TROUBLE SHOOTING
TROUBLE/INDICATION
POSSIBLE CAUSE
SUGGESTED REMEDY
No AC output
Inverter is cold
Disconnect load from inverter.
Operate inverter without load for a
few minutes. Reconnect load.
Low battery alarm sounds
continuously
Bad connection or wiring
Tighten all DC connections
Low battery alarm sounds Low battery voltage
Recharge battery. Remove load from
inverter while recharging battery
Motorised power tool won
’
t
start
Excessive start up load
If appliance does not start, then
appliance is drawing excessive
wattage and will not work with
inverter
Motorised power tool does
not operate at correct
speed
purely inductive load
Make the load not purely inductive.
Operate an incandescent lamp at
same time as motor
Television/Radio
interference
Snow in picture, buzz in
speaker
Keep inverter and antenna distant
from each other. Use shielded
antenna cable. Connect antenna to
amplifier
(Applicable in the European Union and othor European countries with separate
collection systems)
This marking shown on the product or Its literature, indicates that It should not be disposed with
other household wastes at the end of its working life. To prevent possible harm lo the
environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material
resources.
Household users should contact either the retailer where they purchased this product, or their
local government office, for details of where and how they can take this item for environmentally
safe recycling.
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)