Testing is the only definitive way of determining if a specific load can be started and how long it
will run. The inverter is fitted with overload protection so will simply shut down if overloaded. To
restart the unit after overloading remove the overload and if necessary turn the power switch off
and then on.
Battery operating time.
With a typical vehicle battery, a minimum operating time of 2 to 3 hours can be expected. In most
instances, 5 to 10 hours of operating time is achievable however it is recommended that the
operator starts the vehicle every 2 to 3 hours to recharge the battery system thus guarding
against unexpected equipment shut down and ensuring that there is still sufficient power to start
the engine. The inverter's built in alarm will sound if the DC voltage drops below 10.5V. The
inverter can be used whether or not the vehicles engine is running however the inverter will not
operate whilst the engine is being turned over as battery voltage drops substantially whilst the
engine is being started. In most cases the inverter can be left connected to the battery when not
in use as it draws very little current, however if the vehicle is to remain unused for several days
disconnect the inverter from the battery.
In built protection.
Your inverter monitors the following potentially hazardous conditions:
-
Low battery voltage
: This condition is not harmful to the inverter but could damage the power
source. An audible signal will sound when input voltage drops to 10.5V. The inverter
automatically shuts down when input voltage drops to 10.0V. When the power source input
voltage is above 10.5V the inverter may be restarted.
- Over voltage protection
: The inverter will automatically shut down when the input voltage
exceeds 15.5V DC
- Short circuit protection
: The inverter will shut down. Remove the short circuit and the inverter
will reset.
- Overload protection
: The inverter will automatically shut down when the continuous power
consumption is over the rated Max power output.
- Overheating protection
: When the temperature sensor inside the inverter reaches 65
degrees C, the unit will automatically shut down. In this instance, allow at least 15 minutes before
attempting to restart the inverter and always disconnect appliances.
NOTE
:
It is normal for the alarm to sound while the unit is being connected to, or disconnected from the
power source, this is not indicative of a problem.