20
1
2
Pressure switch off
Pressure switch
contacts. have not
closed.
Check if fan starts. If fan
starts OK, check pressure switch.
1
3
Pressure switch on
Pressure switch contacts
Pressure switch is faulty
and is stuck on, or fan has
have not opened after
not turned off.
last heat cycle.
Trouble shooting guide for Techrite ignition pack
Warning:
This is a 240VAC module. All connections to the module are 240V (except ignition cable and
flame sense).
Ensure power is switched off
before checking any connection or replacing any
components.
There is a red LED (light) and a green LED (light) on the blue ignition box. If a fault occurs the sequence
of the flashing red light indicates the fault. These codes are listed below.
The green light indicated the ignition box is sensing the flame
.
Fan Forced Models
The codes above still apply plus the codes below
.
Atmospheric Models
Flash Code Meaning Possible Cause
(Red LED)
Long
1
short
0
Running OK
Appliance running correctly
(Green LED will be on)
2
1
Maximum retries
exceeded
Check spark electrode for damage and
clean if necessary. Check
Unit has tried to light
electrode connection. Check
and not detected flame.
solenoid connections. Check gas
supply.
2
2
Flame fail lockout.
Unit has detected loss
Check electrode, lead
and connection. Check gas supply.
of flame. It has tried
re-ignition and locked out
Installation Instructions Kemlan Power Flue Horizon Gas Fireplaces