background image

Page

 2

 (

Rev

A

 - 

6

/

2012

)

1

2

3

4

5

37

6

7

8

7

23

24

7

9

25

11

10

12

13

13

14

15

16

17

21

22

20

19

18

Item No.

Description

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

Evaporater

Hanger Bracket

Fan

Shroud-Fan

Condenser

Solenoid Valve

Switch-Electrical

Access Panel

Drainage Funnel

Orifice-Fill Ice Bank

Orifice-Water Inlet

Orifice-Water Outlet

Pushbar-Side

Upper Plastic Shroud

Pushbar-Front

Basin

Faucet-Bubbler

Lower Shroud

Compressor

Water Pipe Coupling

Cold Water Thermostat

Orifice-Overflow

Out Water Pipe

   Retaining Screw(M5)

Waste Water Pipe

Bubbler Head

Stream Adjuster

Rubber Seal

Locknut

Non-return Pad

M10 Nut

    Horn Pad

    Stopper

    Fastening Nut

    1/4" PE Pipe

M4 Screw

Wiring Harness

FIGURE 1

FIGURE 2

Содержание KM35 Series

Страница 1: ...PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELEC TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECT...

Страница 2: ...d Valve Switch Electrical Access Panel Drainage Funnel Orifice Fill Ice Bank Orifice Water Inlet Orifice Water Outlet Pushbar Side Upper Plastic Shroud Pushbar Front Basin Faucet Bubbler Lower Shroud Compressor Water Pipe Coupling Cold Water Thermostat Orifice Overflow Out Water Pipe Retaining Screw M5 Waste Water Pipe Bubbler Head Stream Adjuster Rubber Seal Locknut Non return Pad M10 Nut Horn Pa...

Страница 3: ...Page 3 Rev A 6 2012 FIGURE 3 ...

Страница 4: ... 2 1 4 fitting must be connected to the mains supply by means of a water supply valve G not provided SEE FIGURE 3 FILLING INTERNAL ICE BANK 9 Remove the white plugs marked Fill Ice Bank 10 Connect water supply tube into the connector Fill Ice Bank 11 Open the water supply valve G let the water enter the ice bank slowly and fill the ice bank once reach the right level the exceeding water will run o...

Страница 5: ...it remove lower shroud disconnect drain remove four screws from tabs along lower edge of upper shroud unplug two wires and water tube SEE FIG 4 FIG 5 FIG 6 Bubbler To remove the bubbler first disconnect the power supply The underside of the bubbler can be reached through the access panel Item 8 on the underside of the upper shroud Item 14 Remove the access panel by removing the retaining screw ite...

Страница 6: ... When installing replacement bubbler and pedestal tighten Nut only to hold parts snug in position Do Not Overtighten BUBBLER DETAIL 26 27 28 29 30 31 32 33 34 35 LOWER COVER SCREWS BASINASSEMBLY SCREWS SCREWS FIGURE 4 FIGURE 5 ...

Страница 7: ... Rev A 6 2012 Switch Activation Closed Switch Detail Open Switch Detail Note Only side push activation is shown Front push works the same Page 7 ...

Отзывы: