8  remote control features  

Kelvinator Air Conditioning

Light:

Sleep:

Press the "SLEEP" button to activate the "SLEEP" feature.

Press the "SLEEP" button to deactivate the "SLEEP" feature. 

In Cooling mode, the cooling temperature set point will 

increase 1°C per hour after the "SLEEP" mode is selected. 

After two hours, the set temperature will remain constant. 

In Heating mode, the heating temperature set point will 

decrease 1°C per hour after the sleep button is pressed and 

then remain constant.

To change Celsius to Farenheit

With the air conditoner switched off, press the "MODE" and 
"     " buttons simultaneously to switch °C and °F.

caution

NEVER operate the air conditioner without the ai lter, 
as dust/dirt particles can contribute to equipment failure.

Vertical ai

ow adjustment (manually)

To adjust the vertical ai ow direction, adjust any one of the
horizontal louvre blades. When adjusting the horizontal 
louver blades up or down, always keep the top or bottom 
blades horizontal. This can effectively prevent water droplets 
condensing on the front panel of the unit.

Remote Control Operating Instructions:

The hand held remote control unit operates within a range 
of 7 metres (23ft) from the receiver located inside the unit. 
Any obstruction between the receiver and the hand held 
remote may cause signal interference, limiting the ability 
to program the main unit.
Each time a remote control button is pressed, a beep will 
sound indicating a command (signal) is transmitted and 
received on the unit. When the command is received, 
the appropriate function will be displayed (temporarily) 
in the LED display window and the green indicator light 
corresponding to the selection mode will illuminate on 
the main control panel.

Note: 

Note: 

  The LED display will default to show the ambient 

room temperature within 10 seconds of all 
program commands.

Power:

To turn the (air conditioner) power on/off, aim the remote 
control at the receiver (window) on the unit and press the 
"POWER" button.

Mode:

Press the "MODE" button to select either "AUTO", 
"HEATING", "COOLING", "FAN" or "DRY" mode (Cooling 
& Heating model) or "COOLING", "FAN" or "DRY" mode 
(Cooling only model).

Set cooling/heating/auto temperature:

Press the "TEMP" (up/down) buttons to select (increase/
decrease) the required operating temperature, the selected 
temperature will appear (temporarily) in the LED display.
The temperature settings are adjustable between 16

O

and 31

O

C.

Fan:

Press the "FAN" button to select the required operating fan 
speed (HIGH, MED or LOW).

Swing:

Press the "SWING" button to activate the swing feature (the 
vertical louvres will oscillate automatically from side to side). 
Press the "SWING" button again to deactivate the 
"SWING" feature. 

Timer:

Auto: 

Press the "AUTO" button to active the "AUTO" function and 
the unit will be running according to room temperature.

Operating instructions

Press the "TIMER" button to activate the "auto start/auto 
stop" timer function. Under ON status, press the button to 
set timer OFF; Under OFF status, press the button to set 
timer ON. Time setting range is 0.5~24hours.

Follow Me:

Press this button to turn the control panel display On & Off.

Push this button to initiate the “FOLLOW ME” feature, 
which allows the indoor ambient temperature reading to be 
taken from the remote control. The remote control will send 
this signal to the air conditioner every 10 minutes interval 
until press the “FOLLOW ME” button again. The 
air-conditioner will cancel the “FOLLOW ME” feature 
automatically if the indoor unit dose not receive the signal 
from the remote control within a 10 minutes period. 

The display will be On as a default setting.

Содержание KWH53CRF

Страница 1: ...Window Wall Electronic Room Air Conditioner KWH22CRF KWH22HRF KWH27CRF KWH27HRF KWH39CRF KWH39HRF KWH53CRF KWH53HRF KWH60CRF KWH60HRF Refrigerant R32 CARE USE Australians love a Kelvinator...

Страница 2: ...he air conditioner is not intended for use by young children or i rmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner Contact...

Страница 3: ...bles such as gasoline benzene thinner etc It may cause an explosion or fire Ventilate room before operating air conditioner if there is a gas leakage from another appliance It may cause explosion fire...

Страница 4: ...the room well when used together with a stove etc An oxygen shortage may occur Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use...

Страница 5: ...e 4 The unit should be provided with an individual circuit and the circuit breaker fuse rating should be the same as that of the power cord and wall outlet Controls The electronic control keypad will...

Страница 6: ...or light for Auto mode When you select Auto mode a beep will sound indicating this MODE option was selected Temperature settings up Press the keypad to increase the set operating temperature of the un...

Страница 7: ...p is heard from the main unit when initiating program commands from the remote control to the main unit b The main unit does not respond to the remote control program commands Battery Replacement 1 Sl...

Страница 8: ...the main control panel Note Note The LED display will default to show the ambient room temperature within 10 seconds of all program commands Power To turn the air conditioner power on off aim the remo...

Страница 9: ...e air conditioner will stop completely When the power is restored the air conditioner will start automatically with all the previous settings preserved in the memory The treatment of condensed water 1...

Страница 10: ...brick cut away to clear louvres 45 brick cut away to clear louvres Front Louvre support cannot be provided AIR IN AIR OUT 100mm minimum AIR IN OPTION A BRICK WALL AIR OUT A 100mm 100mm IR IN AIR IN T...

Страница 11: ...he slots See Fig 2 Step 2 Remove the frame 1 Remov xing screws from the frame See Fig 3 Screws can be in different positions of the frame for different models usually there are 2 screws at the rear of...

Страница 12: ...cuit breaker is tripped Check the house fuse circuit breaker box and replace the fuse or reset the breaker Power failure If power failure occurs switch off and disconnect unplug the power cord When po...

Страница 13: ...Kelvinator Air Conditioning Specifications 13 Notes...

Страница 14: ...14 notes Kelvinator Air Conditioning Notes...

Страница 15: ...Kelvinator Air Conditioning warranty 15...

Страница 16: ...information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 13 13 49 email customercare electrolux com au web kelvinator com...

Отзывы: