4  prior to operation/operating temperature  

Kelvinator Air Conditioning

Prior to Operation

Preparing for operation

1  Contact an authorised installation specialist for installation.
2  Plug in the power plug properly.
3  Do not use a damaged or non-standard power cord.
4  Do not share the same outlet with other appliances.
5  Do not use an extension cord.
6  

Do not start/stop operation by plugging /unplugging 
the power cord.

Usage

1  

Exposure to direct airflow to occupants, pets or plants 
for an extended period of time could be hazardous to 
their health.

2  

Due to the possibility of oxygen deficiency, ventilate 
the room when used together with stoves or other 
heating devices.

Cleaning and maintenance

1  

Do not touch the metal parts of the unit when removing 
the filter. Injuries can occur when handling sharp 
metal edges.

2  

Do not use water to clean inside the air conditioner. 
Exposure to water can destroy the insulation, leading to 
possible electric shock.

3  

When cleaning the unit, first make sure that the power 
and circuit breaker are turned off.

Operating temperature

Cooling Mode

Indoor

Outdoor

Max.

Min.

Max.

Min.

32°C

17°C

43°C

17°C

Heating Mode

Indoor

Outdoor

Max.

Min.

Max.

Min.

27°C

10°C

24°C

-7°C

Note:  Performance may be reduced outside of these 

operating temperatures.

caution

 

When the air filter is to be removed, do not touch the
metal parts of the unit.

It may cause an injury.

 

Do not clean the air conditioner with water.

Water may enter the unit and degrade the insulation. 
It may cause an electric shock.

 

Ventilate the room well when used together with 
a stove, etc.

An oxygen shortage may occur.

Do not put a pet or house plant where it will be
exposed to direct air flow.

This could injure the pet or plant.

Do not use for special purposes.

Do not use this air conditioner to preserve precision 
devices, food, pets, plants, and art objects. It may 
cause deterioration of quality, etc.

 

Stop operation and close the window in storm 
or hurricane.

Operation with windows opened may cause wetting of 
indoor and soaking of household furniture.

 

Hold the plug by the head of the power plug when
taking it out.

It may cause electric shock and damage.

 

Turn off the main power switch when not using
the unit for a long time.

It may cause failure of product or fire.

Do not place obstacles around air-inlets or inside
of air-outlet.

It may cause failure of appliance or accident.

 

Ensure that the installation bracket of the appliance is 
not damaged due to prolonged exposure.

If bracket is damaged, there is concern of damage due 
to falling of unit.

 

Always insert the filters securely. Clean filter once 
every two weeks.

Operation without filters may cause failure.

Do not use strong detergent such as wax or
thinner but use a soft cloth.

Appearance may be deteriorated due to change
of product colour or scratching of its surface.

Do not place heavy object on the power cord and 
ensure that the cord is not compressed.

There is danger of fire or electric shock.

 

If water enters the unit, turn the unit off and 
disconnect the power, contact a qualified 
service technician.

 

Use caution when unpacking and installing.

Sharp edges could cause injury.

 

Do not drink water drained from air conditioner.

It contains contaminants and could make you sick.

Safety precautions

Содержание KWH53CRF

Страница 1: ...Window Wall Electronic Room Air Conditioner KWH22CRF KWH22HRF KWH27CRF KWH27HRF KWH39CRF KWH39HRF KWH53CRF KWH53HRF KWH60CRF KWH60HRF Refrigerant R32 CARE USE Australians love a Kelvinator...

Страница 2: ...he air conditioner is not intended for use by young children or i rmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner Contact...

Страница 3: ...bles such as gasoline benzene thinner etc It may cause an explosion or fire Ventilate room before operating air conditioner if there is a gas leakage from another appliance It may cause explosion fire...

Страница 4: ...the room well when used together with a stove etc An oxygen shortage may occur Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use...

Страница 5: ...e 4 The unit should be provided with an individual circuit and the circuit breaker fuse rating should be the same as that of the power cord and wall outlet Controls The electronic control keypad will...

Страница 6: ...or light for Auto mode When you select Auto mode a beep will sound indicating this MODE option was selected Temperature settings up Press the keypad to increase the set operating temperature of the un...

Страница 7: ...p is heard from the main unit when initiating program commands from the remote control to the main unit b The main unit does not respond to the remote control program commands Battery Replacement 1 Sl...

Страница 8: ...the main control panel Note Note The LED display will default to show the ambient room temperature within 10 seconds of all program commands Power To turn the air conditioner power on off aim the remo...

Страница 9: ...e air conditioner will stop completely When the power is restored the air conditioner will start automatically with all the previous settings preserved in the memory The treatment of condensed water 1...

Страница 10: ...brick cut away to clear louvres 45 brick cut away to clear louvres Front Louvre support cannot be provided AIR IN AIR OUT 100mm minimum AIR IN OPTION A BRICK WALL AIR OUT A 100mm 100mm IR IN AIR IN T...

Страница 11: ...he slots See Fig 2 Step 2 Remove the frame 1 Remov xing screws from the frame See Fig 3 Screws can be in different positions of the frame for different models usually there are 2 screws at the rear of...

Страница 12: ...cuit breaker is tripped Check the house fuse circuit breaker box and replace the fuse or reset the breaker Power failure If power failure occurs switch off and disconnect unplug the power cord When po...