1   The unit must only be installed by a qualified refrigeration 

mechanic and electrical work carried out by a qualified 
electrician according to local or government regulations 
and in compliance with this manual.

2   If the supply cord is damaged, it must be replaced by 

the manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard.

4   The appliance must be positioned so that the plug 

is accessible.

5   The temperature of refrigerant circuit will be high, 

please keep the interconnection cable away from the 
copper tube.

6    This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person 
responsible for their safety.

 

 Children should be supervised to ensure that they do not 
play with the appliance.

warning

Before obtaining access to terminals, all supply circuits must 
be disconnected.

Please read this installation manual and the user manual 
before installation and store in a handy place for later 
reference. Inside you will find many helpful hints on how to 
install and test the air conditioner properly. 
Electrical work must be carried out by a licensed electrician. 
Be sure to use the correct rating of the power plug and main 
circuit for the model to be installed.
Incorrect installation due to ignoring this instruction will 
cause harm or damage, and the seriousness is classified by 
the following indications.
Meanings of symbols used in this manual are shown below:

warning

This symbol indicates information concerning your  
personal safety

caution

This symbol indicates information on how to avoid 
damaging the appliance

tips and information

This symbol indicates tips and information about  
use of the appliance

environmental tip 

This symbol indicates tips and information about 
economical and ecological use of the appliance

 

This symbol indicates never to do this

 

This symbol indicates always do this

Important safety instructions

Notice for installation

Kelvinator Air Conditioning 

 Important safety instructions/Notes for installation  3

Содержание KSV80HRC

Страница 1: ...Inverter Split Room Air Conditioner Installation Manual KSV26CRC KSV26HRC KSV35CRC KSV35HRC KSV53HRC KSV62HRC KSV70CRC KSV70HRC KSV80HRC Refrigerant R410A...

Страница 2: ...to discard this air conditioner please contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed perso...

Страница 3: ...uits must be disconnected Please read this installation manual and the user manual before installation and store in a handy place for later reference Inside you will find many helpful hints on how to...

Страница 4: ...tic waves are generated by radio equipment welders or medical equipment salt laden air prevails such as close to coastal areas the air is contaminated with industrial vapours and oils the air contains...

Страница 5: ...sions are not adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided The installation must allow for reasonable access space nec...

Страница 6: ...tside the outlet pipe The drain hose should be slanted downward slightly without distortion bulge or fluctuation Do not put the outlet into water Installation of indoor unit Installation of the mounti...

Страница 7: ...om the left or right side of indoor unit cut off the tailings from the chassis when necessary As shown in Fig 1 a Cut off the tailings 1 when routing the wiring only b Cut off the tailings 1 and taili...

Страница 8: ...nt leakage is due to defects in the flaring work Carry out correct flaring work using the following procedure Oblique 90 C Roughness Burr A Cut the pipes and the cable Use the piping kit accessory if...

Страница 9: ...connection green Air purging and leakage test 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of chargi...

Страница 10: ...city is not accurate Operation test 1 Before operation test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off val...

Страница 11: ...less the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii mis...

Страница 12: ...bout Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www ke...

Отзывы: