Kelvinator KSV80HRC Скачать руководство пользователя страница 2

2  Contents  

Kelvinator Air Conditioning

Congratulations and thank you for choosing our Inverter Split 
room air conditioner. We are sure you will find  
your new air conditioner a pleasure to use. Before you use 
the air conditioner, we recommend that you read through  
the entire user manual, which provides the description of  
the air conditioner and its functions.
To avoid the risks that are always present when you use an 
electrical appliance, it is important that the air conditioner  
is installed correctly and that you read the safety instructions 
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet  
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not 
damaged. If in doubt, do not use the air conditioner but  
contact your local Electrolux Customer Care Centre.

environmental tip 

Information on disposal for users

•    Most of the packing materials are recyclable.  

Please dispose of those materials through your local 
recycling depot or by placing them in appropriate 
collection containers.

•    If you wish to discard this air conditioner, please contact 

your local authorities and ask for the correct method  
of disposal.

caution

•    The air conditioner is not intended for use by young 

children or infirmed persons without supervision.

•    Young children should be supervised to ensure that 

they do not play with the air conditioner. 

•    Contact an authorised installer for installation of this unit.
•    Contact an authorised service technician for repair or 

maintenance of this unit.

•    If the power cord is to be replaced, replacement work  

shall be performed by authorised personnel only.

•    Installation work must be performed in accordance  

with the national wiring Standards by authorised 
personnel only.

Conditions of use

This appliance is intended to be used in household and 
similar applications such as:

•    

Staff kitchen areas in shops, offices and other working 
environments

•  

Farm houses

•    

By clients in hotels, motels, and other residential 
type environments

•  

Bed and breakfast type environments

Contents  ............................................................................ 2

Important safety instructions ........................................... 3

Notice for installation ....................................................... 3

Installation ......................................................................... 4

Installation drawing .......................................................... 5

Installation of indoor unit ................................................. 6

Refrigerant pipe connection  ............................................. 8 

Installation of outdoor unit ............................................... 9

Check after installation and operation test .................... 10

Installation and maintenance of HEPA filter ................... 10

Warranty .......................................................................... 11

Congratulations

Contents

Содержание KSV80HRC

Страница 1: ...Inverter Split Room Air Conditioner Installation Manual KSV26CRC KSV26HRC KSV35CRC KSV35HRC KSV53HRC KSV62HRC KSV70CRC KSV70HRC KSV80HRC Refrigerant R410A...

Страница 2: ...to discard this air conditioner please contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed perso...

Страница 3: ...uits must be disconnected Please read this installation manual and the user manual before installation and store in a handy place for later reference Inside you will find many helpful hints on how to...

Страница 4: ...tic waves are generated by radio equipment welders or medical equipment salt laden air prevails such as close to coastal areas the air is contaminated with industrial vapours and oils the air contains...

Страница 5: ...sions are not adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided The installation must allow for reasonable access space nec...

Страница 6: ...tside the outlet pipe The drain hose should be slanted downward slightly without distortion bulge or fluctuation Do not put the outlet into water Installation of indoor unit Installation of the mounti...

Страница 7: ...om the left or right side of indoor unit cut off the tailings from the chassis when necessary As shown in Fig 1 a Cut off the tailings 1 when routing the wiring only b Cut off the tailings 1 and taili...

Страница 8: ...nt leakage is due to defects in the flaring work Carry out correct flaring work using the following procedure Oblique 90 C Roughness Burr A Cut the pipes and the cable Use the piping kit accessory if...

Страница 9: ...connection green Air purging and leakage test 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of chargi...

Страница 10: ...city is not accurate Operation test 1 Before operation test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off val...

Страница 11: ...less the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii mis...

Страница 12: ...bout Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www ke...

Отзывы: