Kelvinator KSV26CRC Скачать руководство пользователя страница 4

4  Installation  

Kelvinator Air Conditioning

Safety precautions

1   A dedicated power supply circuit should be used for 

products not supplied with a service cord and plug in 
accordance with local electrical safety regulations.

3   The unit must be reliably earthed and connected to 

the special earth device by a qualified electrician.

4   The circuit breaker must have the functions of magnetic 

tripping and heat tripping to prevent short circuit 
and overload.

5   The appliance must be installed in accordance with 

national wiring regulations.

6   Including a circuit breaker with suitable capacity, please 

note the following table.

Model

Circuit Breaker (Amps)

KSV26CRC

10

KSV26HRC

10

KSV35CRC

10

KSV35HRC

10

KSV53HRC

15

KSV62HRC

15

KSV70CRC

20

KSV70HRC

20

KSV80HRC

20

Note:
•   Make sure the live wire, neutral wire and earth wire in 

the power socket are properly connected.

•   Inadequate or incorrect electrical connections may cause 

electric shock or fire.

Earthing requirements

1   Air conditioner is type I electric appliance. Please ensure 

the unit is reliably earthed.

2   The yellow-green wire in air conditioner is the earthing 

wire which cannot be used for other purposes. Improper 
earthing may cause electric shock.

3   The earth resistance should adhere to the national 

wiring regulation.

4   The user's power must have reliable earthing terminal. 

Do not connect the earthing wire with the following: 
1. Water pipe 
2. Gas pipe 
3. Contamination pipe

Installation

Installation site instructions

A proper installation site is vital for correct and efficient 
operation of the unit. Avoid the following sites where:
•   strong heat sources, vapours, flammable gas or volatile 

liquids are emitted.

•   high-frequency electro-magnetic waves are generated 

by radio equipment, welders or medical equipment.

•  salt-laden air prevails (such as close to coastal areas).
•  the air is contaminated with industrial vapours and oils.
•   the air contains sulphurous gas such as in hot spring 

zones.

•  corrosion or poor air quality exists.

Installation site of indoor unit

1   The air inlet and outlet should be away from the 

obstructions. Ensure the air can be blown through the 
whole room.

2   Select a site where the condensing water can be 

easily drained out, and where it is easily connected for 
the outdoor unit.

3  Select a place where it is out of reach of children.
4   Select the place where the wall is strong enough to 

withstand the full weight and vibration of the unit.

5   Be sure to leave enough space to allow access for routine 

maintenance. The installation site should be 2m or more 
above the floor.

6   Select a place about 1m or more away from a TV set or 

any other electric appliance.

7  Select a place where the filter can be easily taken out.
8   Make sure that the indoor unit is installed in accordance 

with installation dimension instructions (refer to page 5).

9   Do not use the unit in the laundry or by a swimming 

pool etc.

Installation site of outdoor unit

1   Select a site where noise and outflow air emitted by unit 

will not annoy neighbors.

2   Select a site where there is sufficient ventilation.
3   Select a site where there is no obstruction blocking the 

inlet and outlet.

4   The site should be able to withstand the full weight 

and vibration of the unit.

5   Select a dry place, but do not expose the unit to direct 

sunlight or strong wind.

6   Make sure that the outdoor unit is installed in accordance 

with the installation instructions, and is convenient for 
maintenance and repair.

7   Ensure that the height difference between indoor and 

outdoor units complies with the table on page 8.

8  Select a place where it is out of reach of children.

Содержание KSV26CRC

Страница 1: ...Inverter Split Room Air Conditioner Installation Manual KSV26CRC KSV26HRC KSV35CRC KSV35HRC KSV53HRC KSV62HRC KSV70CRC KSV70HRC KSV80HRC Refrigerant R410A ...

Страница 2: ... to discard this air conditioner please contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner Contact an authorised installer for installation of this unit Contact an authorised...

Страница 3: ...cuits must be disconnected Please read this installation manual and the user manual before installation and store in a handy place for later reference Inside you will find many helpful hints on how to install and test the air conditioner properly Electrical work must be carried out by a licensed electrician Be sure to use the correct rating of the power plug and main circuit for the model to be in...

Страница 4: ...etic waves are generated by radio equipment welders or medical equipment salt laden air prevails such as close to coastal areas the air is contaminated with industrial vapours and oils the air contains sulphurous gas such as in hot spring zones corrosion or poor air quality exists Installation site of indoor unit 1 The air inlet and outlet should be away from the obstructions Ensure the air can be...

Страница 5: ...nsions are not adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided The installation must allow for reasonable access space necessary for proper installation of the unit include the minimum permissible distances to adjacent parts Space to the wall 200cm above 30cm above Space to the obstruction Air outlet side e v o b 50cm a...

Страница 6: ...outside the outlet pipe The drain hose should be slanted downward slightly without distortion bulge or fluctuation Do not put the outlet into water Installation of indoor unit Installation of the mounting plate 1 The mounting plate must be installed horizontally As the water tray s outlet for the indoor unit is two way during installation the indoor unit should slightly slant to water tray s outle...

Страница 7: ...rom the left or right side of indoor unit cut off the tailings from the chassis when necessary As shown in Fig 1 a Cut off the tailings 1 when routing the wiring only b Cut off the tailings 1 and tailings 2 when routing both the wiring and piping 2 Take out the piping from body case wrap the piping power cords drain hose with the tape and then make them pass through the piping hole As shown in Fig...

Страница 8: ...igerant leakage is due to defects in the flaring work Carry out correct flaring work using the following procedure Oblique 90 C Roughness Burr A Cut the pipes and the cable Use the piping kit accessory if applicable or pipes purchased locally Measure the distance between the indoor and the outdoor unit Cut the pipes a little longer than the measured distance Cut the cable 1 5m longer than the pipe...

Страница 9: ... connection green Air purging and leakage test 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open the handle of Lo manifold valve 4 Open the vacuum pump for vacuumisation At the beginning slightly loosen joint nut of low pressure valve to check if there is air ...

Страница 10: ...acity is not accurate Operation test 1 Before operation test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off valves of the connection pipes should be opened d All the impurities such as scraps and waste must be cleared from the unit 2 Operation test method a Switch on power and press ON OFF button on the remot...

Страница 11: ...nless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi inco...

Страница 12: ...about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: