Kelvinator Air Conditioning

  installation instructions

Installation and maintenance of 

HEPA filter

Check after installation and 

operation test

Check after installation

Items to be checked

Possible malfunction

Has the unit been 

fixed firmly? 

The unit may drop, shake 

or emit noise.

Have you done the 

refrigerant leakage test? 

It may cause insufficient 

cooling (heating).

Is thermal insulation 

sufficient?

It may cause condensation.

Is water drainage 

satisfactory?

It may cause water leakage.

Is the voltage in accordance 

with the rated voltage 

marked on the nameplate?

It may cause electric 

malfunction or damage 

the unit.

Is the electric wiring or 

piping connection installed 

correctly and securely?

It may cause electric 

malfunction or damage 

the parts.

Has the unit been 

securely earthed?

It may cause electrical 

leakage.

Is the power cord specified?

It may cause electric 

malfunction or damage 

the parts.

Is the inlet or outlet 

blocked?

It may cause insufficient 

cooling (heating).

Is the length of connection 

pipes and refrigerant 

capacity recorded?

The refrigerant capacity is 

not accurate.

Operation test

1  Before operation test
 

a.  Do not switch on power before installation is 

finished completely.

 

b.  Electric wiring must be connected correctly 

and securely.

 

c.  Cut-off valves of the connection pipes should 

be opened.

 

d.  All the impurities such as scraps and waste must be 

cleared from the unit.

2  Operation test method
 

a.  Switch on power and press "ON/OFF" button on the 

remote controller to start the operation.

 

b.  Press MODE button to select the COOL, HEAT (not 

available with cooling only models), FAN to check 
whether the operation is normal or not.

Installation of HEPA filter

1   Lift up the front panel from the two ends of it, as shown 

by the arrow direction, and then remove the air filter

Air filter

HEPA 

filter

2  Attach the HEPA filter onto the air filter

Air filter

HEPA 

filter

3   Install the air filter properly along the arrow direction in 

the diagram below, and then close the panel

Air filter

HEPA 

filter

Cleaning and maintenance

Remove the HEPA filter and reinstall it after cleaning 
according to the installation instructions. Don't use a brush 
or harsh cleaners to clean the filter. After cleaning, dry the 
filter in the shade.

Service life

The general service life for the HEPA filter is about one year 
under normal conditions.

Содержание KSV26CRC

Страница 1: ...Inverter Split Room Air Conditioner Installation Manual KSV26CRC KSV26HRC KSV35CRC KSV35HRC KSV53HRC KSV62HRC KSV70CRC KSV70HRC KSV80HRC Refrigerant R410A ...

Страница 2: ... to discard this air conditioner please contact your local authorities and ask for the correct method of disposal caution The air conditioner is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner Contact an authorised installer for installation of this unit Contact an authorised...

Страница 3: ...cuits must be disconnected Please read this installation manual and the user manual before installation and store in a handy place for later reference Inside you will find many helpful hints on how to install and test the air conditioner properly Electrical work must be carried out by a licensed electrician Be sure to use the correct rating of the power plug and main circuit for the model to be in...

Страница 4: ...etic waves are generated by radio equipment welders or medical equipment salt laden air prevails such as close to coastal areas the air is contaminated with industrial vapours and oils the air contains sulphurous gas such as in hot spring zones corrosion or poor air quality exists Installation site of indoor unit 1 The air inlet and outlet should be away from the obstructions Ensure the air can be...

Страница 5: ...nsions are not adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided The installation must allow for reasonable access space necessary for proper installation of the unit include the minimum permissible distances to adjacent parts Space to the wall 200cm above 30cm above Space to the obstruction Air outlet side e v o b 50cm a...

Страница 6: ...outside the outlet pipe The drain hose should be slanted downward slightly without distortion bulge or fluctuation Do not put the outlet into water Installation of indoor unit Installation of the mounting plate 1 The mounting plate must be installed horizontally As the water tray s outlet for the indoor unit is two way during installation the indoor unit should slightly slant to water tray s outle...

Страница 7: ...rom the left or right side of indoor unit cut off the tailings from the chassis when necessary As shown in Fig 1 a Cut off the tailings 1 when routing the wiring only b Cut off the tailings 1 and tailings 2 when routing both the wiring and piping 2 Take out the piping from body case wrap the piping power cords drain hose with the tape and then make them pass through the piping hole As shown in Fig...

Страница 8: ...igerant leakage is due to defects in the flaring work Carry out correct flaring work using the following procedure Oblique 90 C Roughness Burr A Cut the pipes and the cable Use the piping kit accessory if applicable or pipes purchased locally Measure the distance between the indoor and the outdoor unit Cut the pipes a little longer than the measured distance Cut the cable 1 5m longer than the pipe...

Страница 9: ... connection green Air purging and leakage test 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open the handle of Lo manifold valve 4 Open the vacuum pump for vacuumisation At the beginning slightly loosen joint nut of low pressure valve to check if there is air ...

Страница 10: ...acity is not accurate Operation test 1 Before operation test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off valves of the connection pipes should be opened d All the impurities such as scraps and waste must be cleared from the unit 2 Operation test method a Switch on power and press ON OFF button on the remot...

Страница 11: ...nless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi inco...

Страница 12: ...about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Отзывы: