These steps are to be followed after the installation of the 
gas continuous flow hot water system to ensure its safety 
and performance. If the hot water system cannot be setup to 
perform correctly as specified in this manual, please call the 
service centre (number located in the warranty section of this 
manual) for further instructions. 

 

      

      

      

      

 

 

 

gate or ball 

valve on inlet

drain plug

filter

1.  Remove and clean the filter located on the cold water 

inlet to the water heater (refer to page 11 of this manual).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      

      

      

      

 

 

 

2.  Open all the hot taps and fixtures in the house.
 

 

 

 

 

3.  Open the cold water isolation valve fully at the inlet to the 

water heater

4.  Check all pipe work for leaks and stop the leaks as 

necessary

5.  Once all the air has been forced out of the system and 

water is flowing freely from every hot tap or fixture, close 
all hot taps and fixtures

6.  Open the gas isolation valve fully by hand at the inlet to 

the water heater

 

 

 

 

 

 

 

 

 

 

 

 

7.  Check the gas pipe work for leaks and stop the leaks as 

necessary 

caution

If there is a gas leak that cannot be stopped, do not try to 
start the water heater. Do not touch any electrical switches, 
use a mobile phone or any other ignition source. Close the 
main gas isolating valve to the premises and walk a safe 
distance away. Call the gas supplier and follow the gas 
supplier’s instructions.

8.  Check the inlet gas pressure (refer page 10 of this 

manual).

9.  Plug the power cord into the socket outlet and switch on 

the electrical supply.

 

10. Open a hot water tap or fixture.
 

•  If there is sufficient water flow the water heater  
  should start up automatically

11.  Check each hot water tap or fixture to ensure that there 

is sufficient flow to operate the water heater (minimum 3 
litres per minute).

12. Check the temperature of the hot water at each hot tap or 

fixture intended primarily for personal hygiene to ensure 
the temperature is not higher than 50°C.

Commissioning instructions

16  commissioning instructions 

 Kelvinator Gas Continuous Flow hot water system

filter

Содержание KGC20BNA

Страница 1: ...Gas Continuous Flow Hot Water System Installation Manual...

Страница 2: ...s gas continuous hot water system please contact your local authorities and ask for the correct method of disposal caution The hot water system is not intended for use by young children or infirm pers...

Страница 3: ...n concerning use by a person responsible for their safety Children should be supervised to ensure that they do not play with the gas continuous flow hot water system This symbol indicates never to do...

Страница 4: ...y or loss of life 1 The gas continuous flow hot water system does not have a pilot It is equipped with an internal ignition device that automatically lights the burner Do not try and light the burner...

Страница 5: ...GC26KNA KGC26SNA KGC26BLA KGC26KLA KGC26SLA Capacity L min 20L min 26L min Gas Input MJ h 160 195 Supply Inlet Pressure kPa Nat Gas 1 13 min 1 13 min 2 75 max 2 75 max Supply Inlet Pressure kPa LPG 2...

Страница 6: ...A KGC20KLA KGC20SNA KGC20SLA 124mm 490mm 520mm 31mm power 47mm gas 133mm 94mm 60mm 198mm 350mm top fixing positions top fixing positions 330mm hot 98mm 70mm 108mm 30mm cold gas 335mm 19mm 37mm 49mm co...

Страница 7: ...Exterior view KGC26BNA KGC26BLA KGC26KNA KGC26KLA KGC26SNA KGC26SLA power cold 84mm 34mm gas 124mm 133mm hot 41mm hot 49mm cold 490mm 520mm 25mm power 44 5mm gas 350mm 37mm 19mm 198mm 330mm 94mm 60mm...

Страница 8: ...and 70 C models The water heater requires a fireproof back plate if installed on timber wall Selecting an installation location Carefully read this section before selecting the installation location a...

Страница 9: ...ll fan assisted flue appliances in the direction of discharge 1500 k From a mechanical air inlet including a spa blower 1000 n Vertically below an openable window non mechanical air outlet or any othe...

Страница 10: ...onnect any water lines to the gas inlet It may be critically damaged power cord gas inlet supply gas valve Sizing and connection Check the gas type label to make sure that the water heater was built f...

Страница 11: ...systems A manual shut off valve must be installed on the cold water inlet to the water heater between the main water supply line and the water heater Only a gate valve or a ball valve is to be used on...

Страница 12: ...rules 5 The insulation of the fixed wiring must be protected by insulating sleeving having an appropriate temperature rating 6 If the supply cord is to be replaced this must be done by a service techn...

Страница 13: ...n or water heater the remote controller will display a numerical error code Main remote controller model KGCMRCA KGCMRCA must be installed inside as it is NOT water resistant Allows the output tempera...

Страница 14: ...to attach the remote control to gyprock you should use the anchor plug use the fork terminals 25mm remote control wiring connector base 83 5mm 45mm warning The remote controller must be installed insi...

Страница 15: ...onnect remote control wires to remote terminals directly There is no polarity in the terminations plastic cover KGCMRCA typical cable layout remote control terminal remote control cable Remove the pla...

Страница 16: ...inlet to the water heater 7 Check the gas pipe work for leaks and stop the leaks as necessary caution If there is a gas leak that cannot be stopped do not try to start the water heater Do not touch a...

Страница 17: ...n to be handed to the customer or left in a suitable location on the premises If the customer is available they are to be instructed on the safe and correct operating of the water heater and any auxil...

Страница 18: ...o keep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Fluctuation in hot water temperature Is...

Страница 19: ...he bottom left hand side of the cabinet and the error codes can be read from the LED on the PCB Error Codes on the PCB The LED on the PCB Symptom LED light blinks once Incorrect dipswitch setting gas...

Страница 20: ...20 notes Kelvinator Gas Continuous Flow hot water system Notes...

Страница 21: ...Kelvinator Gas Continuous Flow hot water system notes 21 Notes...

Страница 22: ...22 notes Kelvinator Gas Continuous Flow hot water system Notes...

Страница 23: ...is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a clai...

Страница 24: ...er information about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux c...

Отзывы: