background image

Kelvinator gas continuous flow hot water system

  freeze prevention    9

This water heater comes equipped with heaters that prevent 
the water heater from freezing. For this freeze prevention 
system to operate there has to be electrical power to the 
water heater. The freeze prevention device will not work if the 
electrical power source is disconnected. The water heater 
has been rated for temperatures down to -15°C in a wind  
free environment. 

caution

The pipe heaters are located on the water heater only. 
Any hot or cold water pipes located outside of the 
water heater will not be protected. Properly protect and 
insulate these pipes to ensure they do not freeze. 

Winter shutdown 

If you will not be using your gas continuous flow system for 
a long period of time or if the temperatures is expected 
to drop below -15°C with the wind chill factor, turn off your 
water heater and drain it of water. This will keep your water 
heater from freezing and being damaged.

Follow these instructions carefully: 

1.  Close the manual gas shut off valve. 
2.  Turn off the power supply to the system. 
3.  Close the manual water shut off valve located on the 

water supply line. 

4.  Open all hot water taps in the house. (Bathroom, kitchen, 

laundry room, etc.). When the water flow has ceased, 
close all hot water taps. 

5.  Have a bucket or pan to catch the water from the water 

heater’s drain plugs. Unscrew the drain plugs to drain all 
the water out of the water heater. 

6.   Wait a few minutes to ensure all water has completely 

drained from water heater. 

7.   Securely screw the drain plugs back into place.  

Hand-tighten only.

      

      

      

      

 

 

 

manual  

water 

valve

drain plug

hot

gas

power supply

cold

manual 

gas valve

When it is safe to use the water heater again: 

 •  Ensure that power is switched off to the water heater or 

that it is unplugged

•  Make sure all hot water taps are closed and the drain 

plugs are securely attached. 

•  Purge the water line of debris. 
•  Turn on the manual water control valve located on the 

water supply line and check for leaks. 

•  Open all the hot water taps to verify water flows to the 

taps. Close hot water taps. 

•  Turn on the manual gas control valve located on the gas 

supply line. 

•  Turn on the power supply to the water heater.

Freeze prevention

Содержание KGC20BN Series

Страница 1: ...Gas Continuous Flow Hot Water System User Manual...

Страница 2: ...l indicates tips and information about economical and ecological use of the hot water system environmental tips Information on disposal for users Most of the packing materials are recyclable Please di...

Страница 3: ...symbol indicates always do this warning Connect with power properly Otherwise it may cause electric shock or fire due to excess heat generation Always ensure effective earthing No earthing may cause...

Страница 4: ...ds AS3498 provides full details of the requirements for the supply of controlled temperatures to bathrooms and is required to be conformed to under all Australian plumbing codes Do not store or use ga...

Страница 5: ...ssist you in quoting its model number Rating label position Serial number label position Gas type label position MODELS KGC20 KGC26 Capacity L min 20L min 26L min Gas Input MJ h 160 195 Inlet Supply P...

Страница 6: ...check for leaks Once water is flowing freely from the open hot tap or fixture indicating that all air has been dispelled from the system close the open hot water tap or fixture Open the gas isolation...

Страница 7: ...filter of any debris Refer to page 10 for instructions 1 Fully open the manual water control valve on the water supply line 2 Open a hot water tap to verify that water is flowing to that tap then turn...

Страница 8: ...erature by using the remote controller and mixing cold water as required Note If the Burner On display indicator is lit for safety reasons the temperature on the MAIN controller will not be able to be...

Страница 9: ...e the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve located on the water supply line 4 Open all hot water taps in the house Bathroom kitch...

Страница 10: ...r any flammable vapours and liquids Water heater draining and filter cleaning 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve 4...

Страница 11: ...eep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Is the gas inlet filter in the water heate...

Страница 12: ...12 notes Kelvinator gas continuous flow hot water system Notes...

Страница 13: ...Kelvinator gas continuous flow hot water system notes 13 Notes...

Страница 14: ...14 notes Kelvinator gas continuous flow hot water system Notes...

Страница 15: ...is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a clai...

Страница 16: ...formation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au...

Отзывы: