background image

8  normal operation  

Kelvinator gas continuous flow hot water system

Normal operation

Note: The temperature setting can only be changed by the 

controller if the priority lamp is lit. If multiple remote controllers 

are installed, you can transfer the priority by pressing the 

“Priority” button on the relevant controller but only if there 

is no water flowing through the water heater (close all open 

hot taps or fixtures). Each controller can individually store a 

temperature setting but when the priority setting is transferred 

to the MAIN controller and the previous setting was set to 

above 50°C, it will become 50°C. When the priority setting is 

transferred to a SHOWER or ENSUITE controller, if the previous 

setting was 42°C or above, for safety reasons it will become 

42°C. If a tempering valve has been installed, the hot water 

flowing through the tempering valve will not be able to go 

above the setting set on the tempering valve e.g. 50°C.

 

warning

Water temperatures above 50°C can cause severe burns, 

scalding or death. Children and disabled or elderly 

persons are particularly at risk of being injured. Feel the 

water temperature before bathing or showering and do 

not leave children or disabled persons unsupervised. 

A tempering valve must be installed on the hot water 

system in order to temper any water supplying fixtures 

primarily used for the purposes of personal hygiene as 

per the Australian standards.

4.  Open a hot water tap or fixture.
5.  Ensure the “Burner On” display indicator is lit.
6.  Adjust the water temperature by using the remote 

controller and mixing cold water as required.

Note: If the "Burner On" display indicator is lit, for safety 

reasons the temperature on the MAIN controller will not 

be able to be increased above 50°C. If using a SHOWER or 

ENSUITE controller, for safety reasons the temperature will not 

be able to be increased above 42°C. If these temperatures are 

desired, first close all hot water taps or fixtures then increase 

the temperatures as desired.

7.  Close the hot water tap or fixture.
8.  Ensure the “Burner On” display indicator is off.

priority lamp

priority button

ON/OFF button

burner on 
lamp

display set temperature

Please note the following flow rates to properly operate the 
hot water system:
•  Flow rate to activate the water heater:  

3.0 litres per minute 

•  Flow rate to keep the water heater running: 

2.5 litres per minute 

Without remote controllers installed

 1.  Open a hot water tap. 

 

 

 

 

2.   Mix cold water with the hot to get the correct 

temperature water. 

 

 

 

 

 

3.   Close the hot water and cold water taps.

 

 

 

 

 

With remote controller(s) installed

1.  Press the “On/Off” button to activate the display on the 

controller.

2.  Press the “Priority” button and ensure the priority lamp is 

lit on the remote controller being used. Once the priority 

lamp is lit confirm that the set temperature is displayed 

on the controller(s).

3.  Set your desired temperature by pressing the "+" and "-" 

buttons. If you are using the MAIN controller the output 

temperature can be adjusted within the range of 37°C to 

60°C. If you are using a SHOWER or ENSUITE controller 

the output temperature can be adjusted within the range 

of 37°C to 50°C.

Note: If you have an "A" series main remote controller installed 

it will have max temperature setting option of 55C.

40

Содержание KGC20BN Series

Страница 1: ...Gas Continuous Flow Hot Water System User Manual...

Страница 2: ...l indicates tips and information about economical and ecological use of the hot water system environmental tips Information on disposal for users Most of the packing materials are recyclable Please di...

Страница 3: ...symbol indicates always do this warning Connect with power properly Otherwise it may cause electric shock or fire due to excess heat generation Always ensure effective earthing No earthing may cause...

Страница 4: ...ds AS3498 provides full details of the requirements for the supply of controlled temperatures to bathrooms and is required to be conformed to under all Australian plumbing codes Do not store or use ga...

Страница 5: ...ssist you in quoting its model number Rating label position Serial number label position Gas type label position MODELS KGC20 KGC26 Capacity L min 20L min 26L min Gas Input MJ h 160 195 Inlet Supply P...

Страница 6: ...check for leaks Once water is flowing freely from the open hot tap or fixture indicating that all air has been dispelled from the system close the open hot water tap or fixture Open the gas isolation...

Страница 7: ...filter of any debris Refer to page 10 for instructions 1 Fully open the manual water control valve on the water supply line 2 Open a hot water tap to verify that water is flowing to that tap then turn...

Страница 8: ...erature by using the remote controller and mixing cold water as required Note If the Burner On display indicator is lit for safety reasons the temperature on the MAIN controller will not be able to be...

Страница 9: ...e the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve located on the water supply line 4 Open all hot water taps in the house Bathroom kitch...

Страница 10: ...r any flammable vapours and liquids Water heater draining and filter cleaning 1 Close the manual gas shut off valve 2 Turn off the power supply to the system 3 Close the manual water shut off valve 4...

Страница 11: ...eep the water heater running Is the gas supply valve fully open Is the filter on the cold water inlet clean Are the fixtures clean of debris and obstructions Is the gas inlet filter in the water heate...

Страница 12: ...12 notes Kelvinator gas continuous flow hot water system Notes...

Страница 13: ...Kelvinator gas continuous flow hot water system notes 13 Notes...

Страница 14: ...14 notes Kelvinator gas continuous flow hot water system Notes...

Страница 15: ...is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC 6 Proof of purchase is required before you can make a claim under this warranty 7 You may not make a clai...

Страница 16: ...formation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au...

Отзывы: