4 important safety instructions
Kelvinator gas continuous flow hot water systems
warning
If you fail to follow the instructions below, a fire or
explosion may result, causing property damage, personal
injury or loss of life.
• This hot water system is equipped with an ignition device.
Do not try and light the burner manually.
• Prior to operating ensure that there is no evidence of
leaking gas.
What to do if you smell gas:
• Do not light the hot water system
• Do not touch the electric switch
• Immediately contact your gas supplier and follow their
instruction (
DO NOT
use a phone near the suspected leak)
• Do not use tools or other foreign objects to turn the gas
valve knob, this should only be done by hand. If it is not
possible to turn the knob by hand then contact a qualified
service technician. Force or attempted repair may result
in fire or explosion.
FLAMMABLES
FLAMMABLE VAPOURS
Safety before operating
warning
For your safety, please read before operating
• Check the
GAS
and
WATER CONNECTIONS
for leaks
before using it for the first time.
• Open the main gas supply valve to the water heater
using only your hand to avoid any spark. Never use tools.
If the knob will not turn by hand, do not try to force it; call
a qualified service technician. Forced repair may result in
a fire or explosion due to gas leaks.
• Be sure to check next to the bottom of the water heater
because some gases are heavier than air and may settle
towards the floor.
• Check the
GAS PRESSURE
.
• Do not try to light the burner manually. It is equipped with
an electronic ignition device which automatically lights
the burner.
• Check for
PROPER VENTING
and
COMBUSTIBLE AIR
to
the heater.
• Purge the
GAS and WATER LINES
to remove any air pockets.
• Do not use this water heater if any part has been
submersed in water. Immediately call a qualified service
technician to inspect the water heater and to replace any
damaged parts.
• If this water heater is a 70°C model installed as part of
a gas boosted solar hot water system, please refer to
the user manual supplied with that system for safety
regarding the relief valves installed to limit temperature,
pressure and energy.
Ensure the following safety instructions are read and
understood before using this water heater.
warning
Water temperatures above 50°C can cause severe burns,
scalding or death. Feel the water temperature before
bathing or showering. Do not leave children unsupervised.
The Australian Standards AS3498 provides full details of
the requirements for the supply of controlled temperatures
to bathrooms and is required to be conformed to under all
Australian plumbing codes.
• Do not store or use gasoline or other flammables,
vapours or liquids in the vicinity of the gas continuous
flow hot water system.
• Do not reverse the water and/or gas connections as this
will cause damage to the gas valves, and may also cause
severe injury or death.
• Do not use this water heater if it has at any stage been
immersed in water. Immediately call a licensed plumber,
gas fitter or authorized technician to inspect and/or
service the system.
• Do not disconnect the electrical supply if the ambient
temperature drops below freezing. The Freeze Protection
System only works when the water heater is connected to
the power. The warranty is void if the heat exchanger is
damaged as a result of freezing.
• This hot water system is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the hot water system by a person
responsible for their safety.
• Children should be supervised to ensure that they do not
play with the hot water system.
Important safety instructions
Содержание KGC20BLA
Страница 1: ...Gas Continuous Flow Hot Water System User Manual ...
Страница 12: ...12 notes Kelvinator gas continuous flow hot water systems Notes ...
Страница 13: ...Kelvinator gas continuous flow hot water systems notes 13 Notes ...
Страница 14: ...14 notes Kelvinator gas continuous flow hot water systems Notes ...