background image

Kelly Jaguar series KLS-N Sinusoidal Brushless PM Motor Controller User

’s Manual 

   

 

  V2.9 

                                                                                                                                         

 

29

 

Chapter 5    Maintenance   

There  are  no  user-serviceable  parts  inside  the  controllers.  Do  not  attempt  to  open  the 

controller

 

as this  will void  your warranty.  However,  periodic, exterior cleaning of the controller 

should be carried out. 

The controller is a high powered device. When working with any battery powered vehicle, 

proper safety precautions should be taken that include, but are not limited to, proper training, 
wearing  eye  protection,  avoidance  of  loose  clothing,  hair  and  jewelry.  Always  use  insulated 
tools. 

 

5.1 Cleaning 

Although the controller requires virtually no maintenance after properly installation, the following 
minor maintenance is recommended in certain applications. 

• 

Remove power by disconnecting the battery, starting with battery positive. 

• 

Discharge the capacitors in the controller by connecting a load (such as a contactor coil, 
resistor or a horn) across the controller’s B+ and B- terminals. 

• 

Remove any dirt or corrosion from the bus bar area. The controller should be wiped with a 

moist rag. Make sure that the controller is dry before reconnecting the battery. 

• 

Make sure the connections to the bus bars, if fitted are tight. To avoid physically stressing 

the bus bars use two, well-insulated wrenches.

 

5.2 Configuration 

You can configure the controller with a host computer through either an RS232 or USB port.   

• 

Disconnect  motor  wiring  from  controller  for  configuring  existing  parameters  in  the  user 

program or Android APP. If this operation is too much extra job for you, please make sure 

the motor must be stopped before programming. 

• 

The controller may display fault code, but  it doesn't affect  programming or configuration. 

But it will affect the Identification angle operation. Please try to eliminate the error codes 

before Identification angle operation. 

• 

Use  a  straight  through  RS232  cable or  USB  converter provided  by  Kelly  to  connect  to a 

host computer. Provide >+18V to PWR

for a 24V controller, provide >+8V

. Wire power 

supply return(supply negative) to any RTN pin. 

• 

KLS  controller  requires  a  4pin  connector  to  Kelly  RS232  Converter  to  support  the 

communication. And customers may need a Z-TEK USB cable for Tablet with Android OS.

 

Customers may download PC software or Android APP to program the controller 
before running the motor. You may do Identification angle for brushless motor with 
hall  sensors  after  running  the  software  or  Android  APP.  Every  item  in  the 
configuration program can show the explanation automatically when you click it. 
 

Содержание Puma mini KLS-N Series

Страница 1: ...dal Brushless PM Motor Controllers User s Manual Devices Supported MiniKLS2412ND MiniKLS4812ND Mini KLS7220M MiniKLS2412NV MiniKLS4812NV Mini KLS7225M MiniKLS2420ND MiniKLS4820ND MiniKLS7215ND MiniKLS...

Страница 2: ...Features 4 2 3 Specifications 5 2 4 Name Regulation 5 Chapter 3 Wiring and Installation 6 3 1 Mounting the Controller 6 3 2 Connections 10 3 3 Installation Check List 15 Chapter 4 Programmable Paramet...

Страница 3: ...It uses high power MOSFET s and SVPWM and FOC to achieve efficiencies of up to 99 in most cases A powerful microprocessor brings in comprehensive and precise control to the controllers It also allows...

Страница 4: ...hall sensors 10 5 switch inputs which are activated by connection to 12V Default to throttle switch brake switch reversing switch forward switch and Boost switch 11 3 analog 0 5V inputs that default t...

Страница 5: ...current cutback warning and shutdown at configurable high and low battery voltage 13 Aluminum based PCB board with heat sink plate on the bottom of controller 14 Waterproof connectors for small signa...

Страница 6: ...sed to work with BLDC motor with three hall sensors All KLS controllers can do regen brake function by default 24 24V batteries N The motor controller included a plastic cover And KLS N is IP66 rating...

Страница 7: ...36 86V 400A Up to 200A Mini KLS7245ND 48 72V 36 86V 450A Up to 225A Note Depends on conductive heat sink Continuous current can be much higher with airflow Due to supply issues with electronic compone...

Страница 8: ...con grease or some other thermal conductive material to contact surface will enhance thermal performance Proper heat sinking and airflow are vital to achieve the full power capability of the controlle...

Страница 9: ...Jaguar series KLS N Sinusoidal Brushless PM Motor Controller User s Manual V2 9 8 Figure 12 Mini KLS2412NV Mini KLS2420NV Mini KLS4812NV Mini KLS4820NV mounting holes dimensions dimensions in millime...

Страница 10: ...ies KLS N Sinusoidal Brushless PM Motor Controller User s Manual V2 9 9 Figure 3 Mini KLS2425M Mini KLS2430M Mini KLS4825M Mini KLS4830M Mini KLS7220M Mini KLS7225M mounting holes dimensions dimension...

Страница 11: ...dal Brushless PM Motor Controller User s Manual V2 9 10 Figure 1 Mini KLS4840ND Mini KLS4845ND Mini KLS7240ND Mini KLS7245ND mounting holes dimensions dimensions in millimeters 3 2 Connections 3 2 1 P...

Страница 12: ...er program pin2 is used as brake analog regen mode When boost is enable pin2 is used for boost function You may not use two functions at the same time DJ7091Y 2 3 11 Pin Definition 14 REV_SW Reverse s...

Страница 13: ...TN pins are internally connected 2 Meter function is to copy either of hall sensors 3 Switch to 12V is active Open switch is inactive 4 F N R control and three speed function can not be used at the sa...

Страница 14: ...gure 11 KLS N controller standard wiring Battery voltage can be used for controller supply 3 2 3 Optional wiring of KLS N controller The 12V input signal of the pin supplies the second braking functio...

Страница 15: ...ng diagram for motor temperature sensor NOTE KLS controller can support KTY84 130 150 and KTY83 122 thermistors 3 2 4 Communication Port A 4pin connector to RS232 port is provided to communicate with...

Страница 16: ...e checkout Make sure the PWR switch and the brake is off Use well insulated tools Make sure the wire is connected correctly Turn the PWR switch on The fault code will be detected automatically at rest...

Страница 17: ...n7 to batteries for Identification Angle operation Please download the instruction how to use Identification angle function from our website www kellycontroller com support php 4 1 Step 1 1 Low Volt T...

Страница 18: ...ly again Then everything will be fine The motor is ready to be drived by the KLS controller Range 85 or 170 nothing else 6 TPS Low Err Hall active pedal if lower than the value report the fault of TPS...

Страница 19: ...gh Range 60 95 Functional description Set throttle effective ending point Suggestion Set according to the practical situation factory default is 80 5V 4 0V 14 Max output Fre Max output frequency Unit...

Страница 20: ...ctive output the controller will report fault and not operate Suggestion Set according to the practical situation factory default is Disable 21 NTL H Pedal Neutral position High Pedal Disable Only use...

Страница 21: ...oot switch is turned off Please see figure 4 1 Suggestion Set according to the practical situation factory default is Disable Configuration Pin Status Running Status Forward Switch Foot Switch FWD_SW...

Страница 22: ...elp the motor stop on the downhill But usually this function only helps motor stop rolling back too fast Suggestion factory default is Disable 28 Change Direction If the direction is not what you expe...

Страница 23: ...less for KLS N or KLS M model 4 3 Step 3 1 RLS_TPS Brk RLS TPS Braking Percent the percent of Releasing Pedal BRK in max braking Range 0 50 This is used to adjust the regen current of releasing thrott...

Страница 24: ...for PID adjustment If you think the acceleration performance is very very strong please adjust them to a lower value respectively 10 Change Dir brake Value range Enable and Disable It is only useful w...

Страница 25: ...is normal This item is only useful for internal calculation for MCU 246 is about 11 degrees in environment 4 4 How to use Identification angle operation function We must do Identification angle opera...

Страница 26: ...Kelly Jaguar series KLS N Sinusoidal Brushless PM Motor Controller User s Manual V2 9 25 2 Please connect the controller to user program by using an USB to RS232 cable and SM 4A DB9 RS232 Converter...

Страница 27: ...B to RS232 cable and SM 4A DB9 RS232 Converter to connect the controller to an Android Tablet The third option is customers can buy our Bluetooth converter to connect the controller to Android Phone W...

Страница 28: ...g Because the 85 means this controller finished the identification angle operation with the motor in factory before shipment Your motor is different from the motor from controller supplier 5 Please fi...

Страница 29: ...codes such as Identify error hall err etc please return to the first picture of user program Please write 85 instead in identification angle by manual If there are no any error codes you can not writ...

Страница 30: ...e the connections to the bus bars if fitted are tight To avoid physically stressing the bus bars use two well insulated wrenches 5 2 Configuration You can configure the controller with a host computer...

Страница 31: ...n for motor and hall sensors in the user program Table 1 Error Codes Buzzer Error Codes Code Explanation Solution 1 1 Automatic error identification 1 Wrong wiring of motor phase line or hall Please s...

Страница 32: ...t condition like a temporary over current momentarily high or low battery voltage This can happen during normal operation 3 3 Hall throttle is open or short circuit When the throttle is repaired a res...

Страница 33: ...PM Motor Controller User s Manual V2 9 32 Contact Us Kelly Controls Home Page http www KellyController com Download user manual instructions and user program www kellycontroller com support php E mail...

Отзывы: