Kelly KDZ Series/PM/Sep-Ex Motor Controller User’s Manual
V 3.3
19
4.5V.
3,4
¤¤¤ ¤¤¤¤
Non-zero throttle
on direction
change
Controller won’t allow a direction change unless the
throttle or speed is at zero. Fault clears when
throttle is released.
4,1
¤¤¤¤ ¤
Regen
over-voltage
Motor drive is disabled if an over-voltage is detected
during regen. The voltage threshold detection level
is set during configuration.
4,2
¤¤¤¤ ¤¤
Field error
1. Field did not reach the configured current.
2. Field circuit open. Please check field wiring.
4, 3
¤¤¤¤ ¤¤¤
Motor
over-temperature
Motor temperature has exceeded the configured
maximum. The controller will shut down until the
motor temperature cools down.
The Red LED flashes once at power on as a confidence check and then normally
stays Off. “1, 2” means the Red flashes once and after a second pause, flashes twice. The
time between two flashes is 0.5 second. The pause time between multiple flash code
groups is two seconds.
Contact Us:
Kelly Controls, LLC
Home Page:
http://www.kellycontroller.com
E-mail:
Phone:
(01) 224 637 5092