Operating manual 

5

 

To  set  the  pyrometer  to  the  terminal  mode,  simultaneously  hold  down 
the 

Ctrl key

 and press the 

E key

 twice in rapid succession. 

Direct commands have an assigned key. Example: E for emissivity (epsi-
lon).  Submenu  settings  are  shown  in  brackets.  Example: 

[MIXED 

MODE]

 

6.2.1  Main menue 

After starting the terminal or entering "H", the main menu appears: 

------------------------------------------------------------------ 
Mainmenu 
------------------------------------------------------------------ 
0: [QUOTIENT] .................... E: Quick access EPSILON 
1: [LAMBDA 1] .................... A: Quick access FILTER 
2: [LAMBDA 2] .................... T: Quick access Ao1 SOURCE 
C: [I/O] ......................... Y: Quick access Ao1 SCALE BEGIN 
K: [CALIBRATION] ................. Z: Quick access Ao1 SCALE END 
M: [MIXED MODE] 
H: Show this help-site ........... J: Show diagnosis 
W: Show ambient temperature ...... Q: Show calibration data 
X: Show measure temperatures ..... P: Show channel parameters 
------------------------------------------------------------------ 

6.2.2  Parameter/diagnostic overview 

Command "P" shows an overview of the current parameters: 

------------------------------------------------------------------ 
-    PA50 AFxx      500-1400C – 00/xxx HM       - 28.01.13       - 
-

PA50SW001/0   QP 0,95/1,55um  Version 01.80  10.02.15       - 

------------------------------------------------------------------ 
MIX function

 

............... on

Ao 1 source ............. mixed 

MIX range ...  500.0 - 2400.0 C

 Ao 1 scale ..  700.0 - 1700.0 C 

MIX transition 680.0 -  700.0 C

Ao 1 current ...........0-20 mA 

1st  source .......... lambda 1

Ao 2 source ............... off 

2nd  source .......... quotient 
ctrl source .......... lambda 1 

Main Menu 

Submenu 1 

Submenu 2 

Execute the 

command 

Execute the 

command 

Execute the 

command 

press 

[RETURN] 
or [ESC] 

press 

[RETURN] 
or [ESC] 

press 

[RETURN] 
or [ESC] 

Select [KEY] 

Select [KEY] 
Press []
sste[]

Backspace 

Backspace 

 

Enter 

Enter 

Enter 

[ESC] 

[ESC] 

Содержание PYRO CellaTemp PA

Страница 1: ...PYROMETER CellaTemp PA Mixed Mode Function Ident no 1117971 06 2022 MANUAL...

Страница 2: ...Operating manual...

Страница 3: ...Mode 2 4 Factory setting of the mixed mode function 3 5 Adjustment of the measured values 3 6 Setting parameters at the pyrometer 4 6 1 Setting the parameters using the button 4 6 2 Operation of the...

Страница 4: ...Operating manual...

Страница 5: ...start and Measuring range end 2 Mixed mode function for extending the measuring range With mixed mode operation the measuring range can be extended to lower initial temperatures by linking a spectral...

Страница 6: ...mbda 1 L2 Lambda 2 Q Quotient SRC C Selction of the con trolling source L1 Lambda 1 L2 Lambda 2 Q Quotient SAVE Save Save changes exit menu ESC Escape Discard changes exit menu To operate the pyromete...

Страница 7: ...s In order to ensure a linear transition of the measured values the adjust ment must be carried out as follows during commissioning 1 Align the pyrometer to the target object Set the two colour emissi...

Страница 8: ...VE 6 Now use MODE to either apply the changes you have made to the settings SAVE or to close without saving these changes END After that the display panel will resume showing the tem perature reading...

Страница 9: ...Show this help site J Show diagnosis W Show ambient temperature Q Show calibration data X Show measure temperatures P Show channel parameters 6 2 2 Parameter diagnostic overview Command P shows an ov...

Страница 10: ...ixed Mode you can adjust all relevant parameters In the sub menu Mixed Mode you can adjust all relevant parameters Activation deactivation of the temperature calculation Measuring range of the Mixed M...

Страница 11: ...command T in the main menu you can select the source for the analogue output Select 4 for Mixed Mode The display shows the Mixed Mode temperature T Set Analog Out 1 SOURCE 1 Lambda 1 2 Lambda 2 3 Quot...

Страница 12: ...or in part for any purpose whatsoever without prior consent of the author This applies to any form of mechanical or electronic reproduction as well as to electronic transmission in any form through a...

Отзывы: