smart slider - Operating instructions

02. Electric operation

2.1 Principle

2.2  If mode: DEAD MAN'S operation

The horizontally sliding unit is driven by an electric motor that is linked to your sliding mechanism via a toothed belt 
entirely via the flight bar.

The whole movement is controlled via a “dead man's control”, that is, the user must press down the control button 
until the sliding has completed its full cycle. The movement will stop as soon as the control button is released. The 
user is therefore responsible for keeping an eye on the sliding operation, making sure that no one is in the danger 
zone, and immediately release the button in case of abnormal situations.

To open

Give an open command via the control button and hold it down until the sliding part is fully open.
The system stops itself when fully open.

To close

Give a close command via the control button and hold it down until the sliding part is completely closed.
The system stops itself when fully closed.

IF THE CONTROL BUTTON IS RELEASED, THE SLIDING WILL STOP IMMEDIATELY WITH MOVING. 
ALWAYS REMEMBER THERE IS A SMALL DELAY DEPENDING OF THE WEIGHT AND HOW LARGE 
THE LEAF IS.

ALWAYS TAKE CARE, BEFORE AND WHEN OPERATING THE SLIDING UNIT, THAT THE ENTIRE 
SLIDING ZONE IS FREE OF OBSTACLES AND/OR PERSONS AND THIS DURING THE ENTIRE RUN 
PERIOD.

4

Keller minimal windows

®

997-00220 

| 05-2022

Keller minimal windows

®

Содержание LD350

Страница 1: ...smart slider LD350 LD700 05 2022 997 00220 EN Operating instructions...

Страница 2: ...intenance and care Maintenance intervals Faults Decommissioning Disassembly Disposal Maintenance report Commissioning declaration Legal notice Contents Index Title page 2 Keller minimal windows 997 00...

Страница 3: ...00 properly and have it checked at least once a year by a qualified company and have this recorded in writing Visually inspect the smart slider thoroughly at least 1x per month for damage proper funct...

Страница 4: ...no one is in the danger zone and immediately release the button in case of abnormal situations To open Give an open command via the control button and hold it down until the sliding part is fully ope...

Страница 5: ...and stop about 25 cm before the end From here you have to give again an open command via the control button at this time keep the button pressed until the sliding part is fully open The system stops i...

Страница 6: ...IS FREE OF OBSTACLES AND OR PERSONS AND THIS DURING THE ENTIRE RUN PERIOD In the event of a power failure or a defect in the drive and the window is closed and you want to open it you can disengage t...

Страница 7: ...ves and clothing as well as safety shoes when servicing the system Make sure that you can always perform your work stably Secure the installation maintenance area with a safety tape so that third part...

Страница 8: ...ed by a recognized installer or company Maintenance can be divided into two levels Maintenance level 1 User level maintenance WHEN with normal use 1 x per month WHO maintenance that can possibly be ca...

Страница 9: ...mbly still runs smoothly Keep the slide course free of dirt Check whether the flight bar is still nicely and centered between the brushes Check the operation of the automation by checking whether the...

Страница 10: ...ice Disconnect the installation from the electrical mains and ensure that it remains disconnected during maintenance work Bearings guides and moving parts must be lubricated with oil SAE 20 quality Ch...

Страница 11: ...d technician Broken control unit Call an qualified technician Sliding part runs not smoothly Obstacle detected See if running way is completely free of obstacles and dirt Mechanical issue Call an qual...

Страница 12: ...r Remove the top cover Unscrew the carrier bracket Disassemble the beam completely Pay attention sufficient support so that the beam does not fall when unscrewed Carefully lower the motor bar and remo...

Страница 13: ...of construction Commissioning on Manufacturer AB Matic nv Duifhuisstraat 37 3800 Sint Truiden Belgium 2 Customer 3 Installer 4 Sliding unit to be operated Type Dimension Weight 5 Control 6 Working mod...

Страница 14: ...ription of works Signature Signature installation start up adjustments safety checks repairs technician customer Always note works that have been carried out in writing Fill in the maintenance sheet a...

Страница 15: ...Movement is running smoothly Safety devices are in good shape and condition Start Stop function No defects found Adjustments Installation check up Performance tests Checking the assembly Absence of ab...

Страница 16: ...reproduction of common names trade names product descriptions etc in this work does not justify the assumption that such names are to be considered free in the sense of trademark and brand protection...

Страница 17: ...05 2022 Keller Minimal Windows S A 38 40 Route de Wilwerdange L 9911 Troisvierges www minimal windows com...

Отзывы: