25
Operating instructions CellaTemp PKx 6x
EN
10 Menu explanation
10.1 Analogue output
Parameter Function
Explanation
Ao. S
Select source
QUot.
two-colour mode
SPEc.
one-colour mode
(the selected temp� reading source will
be shown on the display)
Ao._
Define lower limit of
temp� span
Analogue start value for scaling
Ao~
Define upper limit of
temp� span
Analogue end value for scaling
Ao.04
Analogue output
0/4 -20 mA
0 -20 mA scaling Analogue output
4- 20 mA scaling Analogue output
End
End
10.2 Switching threshold OUT1
Parameter Function
Explanation
d1.S
OUT1 source
QUot.
two-colour mode
SPEc.
one-colour mode
d1.SP
OUT1
Upper threshold
Upper threshold which activates OUT1
d1.rp
OUT1
Lower threshold
Lower threshold which activates OUT1
D1.Fn
Output function
nc
normally closed
no
normally open
D1.ds
Upper threshold delay
Value in sec (≤ 10 sec in steps of 0.1)
D1.dr
Lower threshold delay
Value in sec (≤ 10 sec in steps of 0.1)
End
End