VIDEO 18XR 35000lm CRI 86 Operating Instructions
3
1� MAGNETIC CONTROL RING
Attention, the black ring controls the operating mode of the light with a magnetic field. Do not place
your compass close to the black control ring (keep a minimum distance of 10cm or 4”).
2� OPERATING MODES
Normal Mode : LOW …� HIGH
- 9 logarithmic Power Levels
Remote Control Mode: “R”
- This is the Mode to control the XR light with the RC1 Remote Control
Basic Workflow to connect XR Light(s) to the RC1 Remote Control:
1. Switch the RC1 remote control to PAIR mode.
2. Switch the Video 18XR light to remote mode “R”, now pairing
is possible during the next 10 seconds.
3. Turn the brightness knob on the RC1 remote control. (Use
the channel you want the light to be paired to).
4. The light confirms a successful pairing with short flashes.
3� CHARGE OF THE BATTERY
Only use the supplied Li-Ion charger to charge the battery. For best results, the battery should be
charged at room temperature. Avoid charging when batteries are still hot after use. Let them cool down
before charging.
Important:
If the battery state of health falls below 75%, always use
the included 12.6V to 12.45V adapter cable when charging.
4� MAINTENANCE OF BATTERY
It is not recommended to discharge the battery after each dive. Complete discharge after every use
may reduce life time of battery. We recommend the following service procedures:
• For storage remove battery from casing.
• Discharge and recharge the battery at least once every 6 months.
• Avoid deep discharge of the battery pack.
• Store battery with approximately a 30-60% partial charge in a dry and cool place.
• Charge fully before each dive.
• The storage of a fully discharged battery may cause permanent damage to the battery.
INSTRUCTIONS