Maximum Supply Voltage
Minimum Supply Voltage
Maximum Supply Voltage
Minimum Supply Voltage
260VAC
190VAC
25VAC or 25VDC
18VAC or 18VDC
The power required to drive the F29 depends on the nature of the supply,
AC or DC and on temperature. The table below gives the maximum power
required from various supplies at 25°C. As temperature increases, the
power required will reduce. For example, at 30°C the power requirement
will be approximately 3% less than the values given in the table. The
measurements expressed in the table represent the maximum required
power with both relays 1 and 2 closed and the LCD backlight and all
indicator lights on.
VOLTAGE LIMITS ON TERMINALS A & N
ELECTRICAL LIMITS
VOLTAGE LIMITS ON TERMINALS LV & N
4mm
Rubber Plug
M20 Gland Nut
Backing Washer
Plug unused cable
glands using the
rubber plugs
(supplied). Fully
tighten the gland nut to
seal the unused cable
port.
Rubber Grommet
Controller Housing
Backing Washer
Cable 7mm to 9mm diameter
Crimp the ears of the
strain relief ring onto
the cable and pull the
cable back into the
slots in the gland
housing.
POWERING THE F29
15