Models 2601B, 2602B, and 2604B 

System SourceMeter

®

 Instruments 

Quick Start Guide 

 

 

 

 

 

Содержание System SourceMeter 2601B

Страница 1: ...Models 2601B 2602B and 2604B System SourceMeter Instruments Quick Start Guide ...

Страница 2: ...ment Category I and Measurement Category II as described in the International Electrotechnical Commission IEC Standard IEC 60664 Most measurement control and data I O signals are Measurement Category I and must not be directly connected to mains voltage or to voltage sources with high transient overvoltages Measurement Category II connections require protection for high transient overvoltages ofte...

Страница 3: ...y be used as shield connections for measuring circuits NOT as protective earth safety ground connections If you are using a test fixture keep the lid closed while power is applied to the device under test Safe operation requires the use of a lid interlock If a screw is present connect it to protective earth safety ground using the wire recommended in the user documentation This symbol on an instru...

Страница 4: ...or installation into a computer should never require cleaning if handled according to instructions If the board becomes contaminated and operation is affected the board should be returned to the factory for proper cleaning and servicing Power and environmental specifications For indoor use only Supply voltage range 100 V to 240 V AC 50 Hz to 60 Hz auto sensing 240 VA maximum Altitude Maximum 2000 ...

Страница 5: ...ance troubleshooting and programming commands The documentation is in PDF format on the CD ROM that is included with the instrument If you do not have Adobe Reader to view the files you can download a free copy of it at http get adobe com reader CD ROM contents The CD ROMs that are included with your instrument contain The Test Script Builder TSB Software and Series 2600B TSB add in which is a sof...

Страница 6: ...Unpack and inspect the instrument To unpack and inspect the instrument 1 Inspect the box for damage 2 Open the top of the box ...

Страница 7: ...e documentation accessories and CD ROMs 4 Carefully lift the instrument out of the box 5 Remove the packaging insert 6 Inspect the instrument for any obvious signs of physical damage Report any damage to the shipping agent immediately ...

Страница 8: ...for the Models 2601B and 2602B 4 Power line cord 5 One 8 pin screw terminal connector for the Model 2601B Two 8 Pin screw terminal connectors for the Models 2602B and 2604B 6 Series 2600B Product Information and Test Script Builder CD ROMs not shown 7 UL safety supplement not shown 8 Safety Precautions not shown 9 Models 2601B 2602B and 2604B System SourceMeter Instruments Quick Start Guide this d...

Страница 9: ...ted for dry locations Read and comply with the specifications of all instruments in the system The overall allowed signal levels may be constrained by the lowest rated instrument in the system For example if you are using a 500 V DC power supply with a 300 V DC rated switch the maximum allowed voltage in the system is 300 V DC Make sure any test fixture connected to the system protects the operato...

Страница 10: ...s 2600B can be used on a bench or in a rack Please see the instructions that came with your rack mount kit if you are installing the Series 2600B in a rack Note that the air intakes for the fan are located on the top cover and side panels of the Series 2600B The space around these areas should be free from obstruction to ensure proper fan operation Connect line power The Series 2600B operates from...

Страница 11: ...ine power 1 Make sure the front panel power switch is in the off 0 position 2 Connect the socket of the supplied power cord to the power connection on the rear panel 3 Connect the plug of the power cord to a grounded AC outlet Turn on the instrument Turn on the instrument by pressing the front panel POWER switch to the on position ...

Страница 12: ...Model 2602B the display will show KEITHLEY Model 2602B Line frequency detection and other startup checks The entire power up process takes approximately 30 seconds to complete When initialization is complete if the instrument is a Model 2602B or a Model 2604B you will see the default display screen shown below If the instrument is a Model 2601B you will see the default display screen shown below ...

Страница 13: ...test DUT for this test Step 1 Set source function range and level If the instrument has two channels Models 2602B or 2604B and is in dual channel display mode press the DISPLAY button once to show only the settings for SMU channel A 1 Press the SRC key You will see a blinking character in the SrcA value field Confirm that mV is displayed if not press the SRC key again 2 While that character is sti...

Страница 14: ...he navigation wheel to set the source value to 20 0000 V and then press the navigation wheel to enter the selection and exit EDIT mode Step 2 Set the source limit 1 Press the LIMIT key You will see a blinking character in the LimA value field 2 While that character is still blinking press the down RANGE keys as needed to select the 10 mA limit range Verify that the source limit value in the LimA f...

Страница 15: ... the Series 2600B automatically selects the best range for the measured value You will briefly see the display shown below and then the main display screen reappears Step 4 Turn the output on Turn the output on by pressing the OUTPUT ON OFF control for Model 2602B and 2604B or Model 2601B The ON OFF indicator LED lights and measurements begin Step 5 Observe measurements Observe the measured voltag...

Страница 16: ... output indicator LED turns off These steps confirm basic functionality of your Model 2601B Model 2602B or Model 2604B instrument Turn the instrument power OFF now For a basic understanding of the of the Series 2600B functionality we strongly recommend that first time users become familiar with the Series 2600B Reference Manual ...

Страница 17: ...cept Model 2400 SCPI commands For more information about loading and running the 2400 personality script see Model 2400 emulation in the Series 2600B Reference Manual What do I do if I lost or formatted the included USB flash drive How can I get another copy of the Model 2400 personality script If you lose or format the USB drive or delete the 2400 personality script you can download the latest ve...