background image

Install the instrument

You can use the Model DMM7510 on a bench or in a rack. If  

you are installing the Model DMM7510 in a rack, please see the 

instructions that came with your rack-mount kit.

To prevent damaging heat build-up and ensure speci

fi

 ed 

performance, make sure there is adequate ventilation and air 

fl

 ow around the instrument to ensure proper cooling. Do not 

cover the ventilation holes on the top, sides, or bottom of  the 

instrument.

Make sure the instrument is positioned so that it is easy to reach 

any disconnecting devices, such as the power cord.

The Model DMM7510 operates from a line voltage of  100 V 

to 240 V at a frequency of  50 Hz or 60 Hz. The line voltage is 

sensed automatically. Before connecting line power, make sure 

the operating voltage in your area is compatible.

Содержание DMM7510

Страница 1: ...Model DMM7510 Quick Start Guide ...

Страница 2: ...ervice personnel Service personnel are trained to work on live circuits perform safe installations and repair products Only properly trained service personnel may perform installation and service procedures Keithley Instruments products are designed for use with electrical signals that are measurement control and data I O connections with low transient overvoltages and must not be directly connect...

Страница 3: ...ry insulated surface capable of withstanding the voltage being measured For safety instruments and accessories must be used in accordance with the operating instructions If the instruments or accessories are used in a manner not specified in the operating instructions the protection provided by the equipment may be impaired Do not exceed the maximum signal levels of the instruments and accessories...

Страница 4: ... equivalent to the original component note that selected parts should be purchased only through Keithley Instruments to maintain accuracy and functionality of the product If you are unsure about the applicability of a replacement component call a Keithley Instruments office for information To clean an instrument remove power from the instrument Use a damp cloth or mild water based cleaner Clean th...

Страница 5: ...esearch and development engineers test engineers and scientists CD ROM contents Each Model DMM7510 instrument is shipped with a Product Information CD ROM part number DMM7510 950 01 The Product Information CD ROM contains Quick Start Guide this document Provides unpacking instructions describes basic connections reviews basic operation information and provides a quick test procedure to ensure the ...

Страница 6: ... CD ROM and optional accessories 4 Remove optional accessories such as rack mount hardware 5 Remove the packaging insert 6 Remove the Model DMM7510 from the box Do not lift the Model DMM7510 by the front bezel Lifting the instrument by the front bezel can cause instrument damage 7 Inspect the instrument for any obvious signs of physical damage Report any damage to the shipping agent immediately ...

Страница 7: ...P Link or ethernet connections 2 KKS 903 01A KickStart Quick Start Guide 3 Model DMM7510 903 01 Quick Start Guide this document 4 Power line cord 5 USB B 1 USB Cable Type A to Type B 1 m 3 28 ft 6 Model DMM7510 Product Information CD ROM 7 Model 1756 Standard Lead Kit 8 071341100 Safety Precautions not shown Refer to the packing list for additional items that may have shipped with your instrument ...

Страница 8: ...cifications of all instruments in the system The overall allowed signal levels may be constrained by the lowest rated instrument in the system For example if you are using a 500 V power supply with a 300 V DC rated switch the maximum allowed voltage in the system is 300 V DC Make sure any test fixture connected to the system protects the operator from contact with hazardous voltages hot surfaces a...

Страница 9: ... the system so they understand all potential hazards and know how to protect themselves from injury During power up in many systems the outputs may be in an unknown state until they are properly initialized Make sure the design can tolerate this situation without causing operator injury or hardware damage To keep users safe always read and follow all safety warnings provided with each of the instr...

Страница 10: ...ilation and air flow around the instrument to ensure proper cooling Do not cover the ventilation holes on the top sides or bottom of the instrument Make sure the instrument is positioned so that it is easy to reach any disconnecting devices such as the power cord The Model DMM7510 operates from a line voltage of 100 V to 240 V at a frequency of 50 Hz or 60 Hz The line voltage is sensed automatical...

Страница 11: ...d outlet may result in personal injury or death due to electric shock Do not replace detachable MAINS supply cords with inadequately rated cords Failure to use properly rated cords may result in personal injury or death due to electric shock The Model DMM7510 must be turned on and allowed to warm up for at least 90 minutes to achieve rated accuracies To connect line power and turn on the instrumen...

Страница 12: ...easure functions DC voltage AC voltage Temperature Continuity DCV ratio DC current AC current Frequency Capacitance 2W resistance 4W resistance Period Diode Digitize functions Digitize voltage Digitize current Go to home screen Go to menu screen ...

Страница 13: ...ion FAQs Next steps Connect Explore Test View communications settings Select where readings are stored Empty Full Run program Change trigger method Continuous Manual Trigger model View events Errors Warnings Information Touch ...

Страница 14: ...Swipe ...

Страница 15: ...Safety Unpack Introduction FAQs Next steps Connect Explore Test Measure settings Swipe screen or for more content Active measure function Press to change Settings for active function ...

Страница 16: ...dings Where do measurements go defbuffer1 defbuffer2 User created buffers 0 1621057 V myBuff1 test2 In the active buffer you selected Default buffers Use a default buffer or create your own View the buffer data MENU MENU ...

Страница 17: ...Safety Unpack Introduction FAQs Next steps Connect Explore Test Save to USB View data Plot data on a graph Touch to display details Stored as a csv file What can you do with buffer data ...

Страница 18: ...Touch to initiate trigger model Smart Scale Touch to scale automatically IDLE Swipe to see Scale Buffer Stats Cursor and Legend Touch any point to see more information You can pinch to zoom in Graphing ...

Страница 19: ...re Test Scale Data Trigger Scaling options Track Latest Similar to oscilloscope triggering Analog Edge Analog Pulse Analog Window External Digital Inputs Select which data to graph Track Group View all Smart Scale Picks scale for you based on available data ...

Страница 20: ...Turn navigation control to change selection 1 Press the HELP key 3 Highlight the object you want help with 2 Getting help ...

Страница 21: ...strument before powering the instrument Safe installation requires proper shields barriers and grounding to prevent contact with test leads Do not apply more than 1000 VPEAK to the INPUT terminals or more than 350 VPEAK to the SENSE terminals Failure to heed this caution may result in instrument damage Do not apply more than 250 VPEAK between INPUT LO and the AMPS input Failure to observe this cau...

Страница 22: ...e in this guide shows you how to make connections to the front panel and short the connections For this example you can make the connections with the Model 1756 Standard Test Lead Kit which is supplied with the Model DMM7510 and the Keithley Instruments Model 8608 Safety Clip Lead Set 1 Make sure the front panel power switch is in the off O position 2 Connect the red lead to the INPUT HI connectio...

Страница 23: ...1 Turn the instrument on 2 On the front panel press the HOME key 3 On the Functions swipe screen select DCV 4 Short the connections The voltage measurements appear in the MEASURE DC VOLTAGE area of the home screen and should read approximately 0 V To view the measurements on the graph screen 1 Press the MENU key 2 Under Views select Graph You can adjust the graph settings using the options in the ...

Страница 24: ...t fixture socket How do I change the command set In addition to the front panel options you can use a remote interface to set up the instrument You can choose one of the following command sets SCPI An instrument specific language built on the SCPI standard TSP A programming language that can be used to send individual commands or combine commands into scripts You cannot combine the command sets As...

Страница 25: ...odel DMM7510 7 1 2 Digit Multimeter Product Information CD ROM which includes the following documents Model DMM7510 User s Manual Provides application examples that you can use as a starting point to create your own applications Model DMM7510 Reference Manual Includes advanced operation topics maintenance information troubleshooting procedures and in depth descriptions of programming commands Kick...

Страница 26: ...ey com cn FRANCE 33 01 69 86 83 60 www keithley fr GERMANY 49 89 84 93 07 40 www keithley de INDIA 080 30792600 www keithley in ITALY 39 049 762 3950 www keithley it JAPAN 81 120 441 046 www keithley jp KOREA 82 2 6917 5000 www keithley co kr MALAYSIA 60 4 643 9679 www keithley com MEXICO 52 55 5424 7907 www keithley com RUSSIA 7 495 664 7564 www keithley ru SINGAPORE 01 800 8255 2835 www keithley...

Отзывы: