Service Information
6-11
Special handling of static-sensitive
devices
CMOS and other high-impedance devices are subject to pos-
sible static discharge damage because of the high-impedance
levels involved. The following precautions pertain specifi-
cally to static-sensitive devices. However, since many
devices in the Model 7022 are static-sensitive, it is recom-
mended that they all be treated as static-sensitive.
1. Such devices should be transported and handled only in
containers specially designed to prevent or dissipate
static buildup. Typically, these devices will be received
in anti-static containers made of plastic or foam. Keep
these parts in their original containers until ready for
installation.
2. Remove the devices from their protective containers
only at a properly grounded work station. Also, ground
yourself with a suitable wrist strap while working with
these devices.
3. Handle the devices only by the body; do not touch the
pins or terminals.
4. Any printed circuit board into which the device is to be
inserted must first be grounded to the bench or table.
5. Use only anti-static type de-soldering tools and
grounded-tip soldering irons.
Principles of operation
The following paragraphs discuss the basic operating princi-
ples for the Model 7022 and can be used as an aid in trouble-
shooting the card. The schematic drawings of the card are
shown on drawing numbers 7021-106 and 7022-176 located
in Section 7.
Block diagram
Figure 6-9 shows a simplified block diagram of the Model
7022. Key elements include the ROM, which contains card
ID and configuration information, matrix relay drivers and
relays, digital I/O output channel drivers, and digital I/O
input channel registers. These various elements are discussed
in the following paragraphs.
To Mainframe
OUTCLOCK
OUTDATA
STROBE
ENABLE
Relay
Drivers
U106-
U109
Relay
Channels
1-30
User
connections
IDCLK
IDDATA
ROM
U110
+3.5V (Steady State)
+5.7 (ª 100 msec during
relay actuation)
Relay
Power
Control
Q100, Q101
U114, U115
+6V, +15V
To/From
Mainframe
To Mainframe
OUTCLOCK
OUTDATA
STROBE
ENABLE
Output
Channel
Drivers
U105
and
U106
Output
Channels
31-40
From
Mainframe
INDATA
INCLOCK
STROBE
ENABLE
Input
Channel
Registers
U101
and
U102
In 1
In 2
In 10
User
connections
Figure 6-9
Model 7022 block diagram
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Содержание 7022
Страница 12: ...iv Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 16: ...viii Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 89: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 90: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 91: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 92: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 93: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 97: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 98: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 100: ...Replaceable Parts 7 8 Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 104: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...
Страница 105: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...