Digital Tracking System
C ontrol Board Re placement
Removal
KP330
Operation Main Menu
1.Turn pressure to lowest setting. Trigger gun to
relieve pressure. Turn prime valve down to DRAIN
position.
4. Press DTS button again and the screen displays
motor temperature.Picture below displays motor
temperature 30 degree Celsius
Relieve pressure, page 5. wait 5 minutes
before servicing.
1.Remove 4 screws and cover.
2.Disconnect display, potentiometer connector.
Also disconnect two red power leads from
ON/OFF switch.
3.Disconnect transducer connector from motor
control board.
4.Use plus driver to loosen the motor connector,
Connector sequence is yellow, green and blue.
5.Remove 6 screws from control board.
2. Press DTS button once to change to pressure
unit PSI.Picture below displays 3300PSI.
5. Press DTS button again to change to pressure
unit BAR.Picture below displays 230bar.
3.Install motor control board with six screws.
2.Apply small amount of thermal compound
to shaded component areas on rear of motor
control board.
Installation
Torque to 17 in-lb (1N·m).
1.Use acetone or similar cleanser to clean sweep
thermal compound from shaded component
areas on rear of motor control board.
3. Press DTS button again and the screen displays
the total motor run hours.Picture below displays
total motor run 8 hours.
10