background image

AIR250 ABDOMINAL 

OPERATION MANUAL

04

It is the sole responsibility of the purchaser of Keiser Corporation equipment to instruct all individuals, whether they are the end-
user or supervising personnel, on proper usage of the equipment. Keiser Corporation recommends that all users of its equipment 
be informed of the following information before use.

1.         Read these instructions.
2.  Heed all warnings.
3.  Follow these instructions.
4.  Intended use of the Air250 Abdominal is for physical 

activity or Physiotherapy (sometimes referred to as 
physical therapy). 

5.  The Air250 Abdominal is intended for individuals aiming to 

maintain and restore maximum movement and functional 
ability throughout their lifespan, including circumstances 
where movement and function are limited by aging, injury, 
pain, disease, disorders, conditions, or environmental 
factors, especially in case of using the Air250 Abdominal 
in physical therapy.

6.  Consult your physician before beginning any exercise 

program.

7.  The Air250 Abdominal is intended for use in training 

areas of organizations where access and control are 

specifically  regulated  by  a  person  responsible  for 

determining the suitability of use and maintenance.

8.  Maximum user weight limit: 441 lbs (200 kg).
9.  Use the Air250 Abdominal indoor in a climate-controlled 

environment only. Keep away from areas of extreme 
humidity.

10.  The use of this Air250 Abdominal for any purpose not 

explicitly specified by the manufacturer in this manual 

is prohibited.

11.  Wear proper exercise clothing and shoes for exercise. 

Avoid wearing loose clothing that might catch on any 
moving parts. Tie long hair back.

12.  The Air250 Abdominal is not a toy. Children shall not 

play with the Air250 Abdominal. Children under 14 years 
old should not use the Air250 Abdominal. Keep children 
and pets clear from the Air250 Abdominal at all times, 
especially while in use. Cleaning and user maintenance 
shall not be performed by children.

13.  The Air250 Abdominal can be used by children age 

14 years and above. Persons with mental disabilities, 
reduced physical, mental, or sensory capabilities, or lack 
of experience or knowledge should not use the Air250 
Abdominal without constant supervision by a spotter/
supervisor.

14.  Proper warm-up required to help prevent injury. This 

Air250 Abdominal should only be used with proper 
instructions. Always maintain good form and control 
during exercise. If you feel pain or are unable to maintain 
good form, stop immediately. Failure to follow these 
instructions could result in injury.

15.  Always maintain control of the Chest Pads (Exercise Arm) 

during exercise. The sudden release of the Exercise Arm 
during exercise will cause the Exercise Arm to recoil 
uncontrollably toward the user and could result in serious 
injury or property damage. Bring the Exercise Arm to 

the start position in a controlled manner to safely end 
exercise. If at any time you are not able to control the 
amount of resistance during exercise, push the left (“-”)
Thumb Button to reduce the resistance.

16.  Never perform Power Test without a proper warm-up. 

This high resistance/high-speed test should only be 
performed with proper instructions (see page 15 “Power 
Test” for complete instruction). Always maintain good 
form and control during the test. If you feel pain or are 
unable to maintain good form, stop immediately. Failure 
to follow these instructions could result in injury.

17.  Never make adjustments to the machine during exercise 

as this may cause muscle strain. Always return the 
Exercise Arm to the start position before making any 
adjustments to help prevent injury.

18.  The highest level of safety can only be ensured if the 

equipment is regularly inspected for damage and wear. 
Always check the equipment before use for proper 
function and any damaged, worn, or broken parts. 
Immediately replace damaged, worn, or broken parts. Do 
not use the Air250 Abdominal until all repairs have been 

completed and tested by a Keiser-certified technician.

19.  Use only replacement parts supplied/recommended 

by Keiser Corporation. Attempting to repair or replace 
any damaged, worn, or broken parts on your own is not 

recommended. A Keiser-certified technician should be 

consulted.

20.  The use of any exercise equipment, including, without 

limitation, Keiser’s strength training equipment in 
which resistance can be changed at any time during the 
repetition, without proper instruction and supervision 
violates the terms of the agreement for the purchase 
of such products. The ability to add resistance anytime 
during a repetition, including, without limitation, the 
ability to do a heavy negative may be dangerous, 
especially for anyone that does not recognize or respect 
the potential danger.

21.  Users, agents, and/or anyone directing the use of the 

Air250 Abdominal shall determine the suitability of the 
Air250 Abdominal for its intended use, and said parties 

are specifically put on notice that they shall assume all 

risk and liability in connection herewith.

22.  If you do not understand these instructions or have 

doubts about the safety of the installation, assembly, 
or use of this product, contact Keiser Customer Support:

1 559 256 8000

[email protected]

keiser.com/support

Telephone and Live Chat
Monday—Friday 7 am to 5:30 pm PST

IMPORTANT SAFETY INFORMATION

Содержание AIR250

Страница 1: ...ABDOMINAL MODELS 002721BP 002721SP OPERATION MANUAL AIR250 STRENGTH CARDIO FUNCTIONAL...

Страница 2: ...E 19 REGULATORY AND COMPLIANCE NOTICES 19_SAFETY NOTIFICATIONS 20_ELECTROMAGNETIC COMPATIBILITY EMC 20_US FCC COMPLIANCE STATEMENT 20_DISPOSAL 23 WARRANTY STATEMENT Keiser the Keiser logo and other tr...

Страница 3: ...y notifications and for faster more accurate warranty service Scan the QR Code to the right to access the interactive online warranty registration form or visit https www keiser com forms warrantyregi...

Страница 4: ...troloftheChestPads ExerciseArm during exercise The sudden release of the Exercise Arm during exercise will cause the Exercise Arm to recoil uncontrollablytowardtheuserandcouldresultinserious injury or...

Страница 5: ...ituation that if not avoided could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related IMPORTANT SAFETY INFORMATION Maintain and do not remove...

Страница 6: ...thmias at rest or aortic aneurysm If the patient is experiencing acute illness febrile condition i e fever or newly occurring pain this represents an absolute contraindication for physical stress In s...

Страница 7: ...Coin Cell Battery quantity 1 Permanently attached not serviceable Contact Keiser Customer Support for service AIR STORAGE TANK The equipment contains an air storage tank air accumulator with the follo...

Страница 8: ...Never connect equipment to an air source capable of exceeding 120 psi 8 27 bar Over pressurizing Keiser pneumatic equipment may cause tubing to burst breakage of equipment abnormal operation or seriou...

Страница 9: ...0 Abdominal Increase Decrease Thumb Buttons Anti Slip Steps Locking Pin Seat Height Adjustment Instruction Placard not shown Power Display Seat Quick Disconnect QD with Tube Cylinder Processor Box Exe...

Страница 10: ...tes the current workout data from the eChip System Messages appear in the RESISTANCE window OFF low power consumption sleep mode Sleep mode occurs after 60 seconds of machine inactivity to help prolon...

Страница 11: ...indicates no data was input to record Settings can only be changed immediately after the eChip is inserted and before your third rep After three reps are performed the setting cannot be changed until...

Страница 12: ...s blank see Battery Replacement procedure page 17 A Thumb Buttons and Display press Thumb Buttons to check for proper operation and the Display powers on B Exercise Arm move freely no loose parts in t...

Страница 13: ...ith your back supported by the Seat backrest feet on the floor or on the Anti Slip Step 3 Grasp the Handles with an underhand grip and adjust the resistance with the Thumb Buttons 4 Curl your upper bo...

Страница 14: ...NTRIC PHASE FORWARD MOVEMENT Flex your upper body forward using your abdominal muscles for the movement Keep your body in contact with the Seat and Chest Pad during movement ECCENTRIC PHASE BACKWARD M...

Страница 15: ...high speed 80 90 of your maximum SET 2 Three repetitions Low resistance high speed 10 of your maximum SET 1 START TEST Press and hold both Thumb Buttons release when 6 r appears in the RESISTANCE wind...

Страница 16: ...tions NOTE Your Keiser Air Compressor not included with your Air250 Abdominal requires basic annual maintenance Contact Keiser Customer Support for Air Compressor operator manual or download at keiser...

Страница 17: ...nt insert the 2 new D batteries into the battery sleeve and install The Power Display will enter a brief test sequence youwillseeaseriesofnumbers flashing 4 Replace the Processor Box cover and screw t...

Страница 18: ...ment is dirty element turns a bright pink or red color Tools required Small Needle Nose Pliers Cutter Tool to cut off flared end of tubes 6 Lubricate Cylinder Rod Wipe the Cylinder Rod clean and coat...

Страница 19: ...ith the disposal of waste products residues including disposal of the equipment itself at the end of its useful life The Air250 Abdominal contains electronic circuit assemblies 2 alkaline D cell batte...

Страница 20: ...AL ELECTROMAGNETIC COMPATIBILITY EMC EMC Notices Statement of Compliance This product has been determined to be compliant with the applicable standards regulations and directives for the countries whe...

Страница 21: ...AIR250 ABDOMINAL OPERATION MANUAL 21 This page intentionally left blank...

Страница 22: ...AIR250 ABDOMINAL OPERATION MANUAL 22 This page intentionally left blank...

Страница 23: ...ay 7 am to 5 30 pm PST or by email at service keiser com Customers outside the United States may obtain warranty information directly through a Keiser international distributor or dealer in the countr...

Страница 24: ...after reading this manual contact Keiser Customer Support 275501_B 1 559 256 8000 service keiser com keiser com support Telephone and Live Chat Monday Friday 7 am to 5 30 pm PST AIR250 ABDOMINAL OPERA...

Отзывы: