AIR250 ABDOMINAL
|
OPERATION MANUAL
16
MAINTENANCE
PREVENTATIVE MAINTENANCE SCHEDULE
Daily
•
Check for safe and proper function of the equipment (perform “Proper Operation
Check,” page 12).
•
Clean the chrome and paint where applicable.
•
Wipe down the equipment with a clean cloth. If necessary, use water and mild soap
(neutral, non-caustic). Target areas that come in contact with sweat. Wipe dry the
equipment.
Monthly
•
Check externally visible screws are fastened properly with no looseness.
•
Clean and lubricate the Cylinder Rod.
•
Inspect Air Line for kinks, tears, or breaks.
•
Inspect Frame for any weakening in weld areas, and other connected areas.
Quarterly
•
Lubricate Pivot Bushings.
•
Inspect Exhaust Muffler and Air Filter for discoloration; replace if necessary.
•
Verify compressor(s) cycle on/off between 100-120 psi (6.89–8.27 bar).
Annually and
other Required
Maintenance
•
For complete instructions, see page 18 “Annual Maintenance.”
•
Battery Replacement. The low battery signal (“Lo-bA”) will appear on the Power Display
when it is time to replace the batteries. Refer to page 17 “Battery Replacement” for
complete instructions.
NOTE: Your Keiser Air Compressor (not included with your Air250 Abdominal) requires
basic annual maintenance. Contact Keiser Customer Support for Air Compressor operator
manual or download at keiser.com/support (search: Air Compressor manuals).
Weekly
•
Check parts most susceptible to wear are not damaged or broken:
–
Upholstery, Linkage System, Thumb Buttons, and Hand Grips.
•
Wax chrome and paint where applicable; wax upholstery.
•
Clean Hand Grips.
•
Inspect Air Line Filter.
IMPORTANT:
Do not use household or industrial cleaners as they contain caustic chemicals that can destroy the paint
finish and cause corrosion. Use only
mild soap/detergent (neutral, non-caustic) to clean.
Contact Keiser Customer Support for replacement parts order, or for any matters regarding the safe operation of your
Air250 Abdominal (see back cover for contact information).
CAUTION: SERVICE AND REPAIR SHALL ONLY BE PERFORMED BY KEISER-CERTIFIED TECHNICIANS.
Failure to follow these instructions can result in serious injury.
CAUTION: THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF THE EQUIPMENT IS
REGULARLY INSPECTED FOR DAMAGE AND WEAR.
Immediately replace damaged, worn, or broken parts. Do not
use the Air250 Abdominal until all repairs have been completed and tested by a Keiser-certified technician.