Step Three: Secure and tie wires and replace lid

Make sure that all of the slack is inside the computer control system box.  Use a zip tie to
bind the wires and hoses on the outside of the box.  Use the wire cutters to cut off the
excess.

zip tie all wires and hoses

Next, gather the four wires inside the box, and arrange them so that the small grey LED
on either side of the box is not blocked from view.  Tie these wires using two or more zip
ties.  Cut the excess from the ties.

secure wires to center of CGS box

Replace the lid on the computer control system box, and return the screw on either side of
the box.

Step Four: Test compressor

Plug the compressor back in, the displays should light up, and if the compressor is below
95 PSI both compressors should start.  The compressor should pump up to approximately
117 PSI and shut off.  When each motor shuts off, you should be able to feel air blow
through the tube that holds the foam, which is located on the same side as the motor that
has just shut off.

Содержание 1031

Страница 1: ...o ensure the proper installation of components and that the instructions are followed for the safety of the users and for maximum machine life or the warranty is void HINTS We use the word Note in thi...

Страница 2: ...turned off it should be parallel to the compressor like this The Mac valve cannot be cleaned Therefore once faulty it must be replaced The Allenair valve functions well in this application and it can...

Страница 3: ...counter clockwise and remove the hose Unscrew nut counter clockwise Next cut the hose to the plastic elbow 3 8 inch from the end of the plastic elbow using the wire cutter cut tubing Repeat steps one...

Страница 4: ...mmet Inside the computer control system box cut all other zip ties holding the four wires Trace each of the wires from the valve to the circuit board There are two per valve four wires total The conne...

Страница 5: ...10 5508 Rev A Service Department 800 888 7009 5 1030 Circuit Board Diagrams Rev A B C Rev D Current...

Страница 6: ...alve installation 1 Adjust and mount new valve 2 Install single to double splitter and electrical wires 3 Secure and tie wires and replace lid 4 Test compressor 5 Note Keep two things in mind when you...

Страница 7: ...y mounting Use the inch open ended wrench to loosen the nut on the top of the new valve Loosen it just enough that you can rotate the red metal housing of the valve turn nut counter clockwise By adjus...

Страница 8: ...If you do not properly attach the hose the pressure from the compressed air will force the hose off the elbow push all the way down on elbow Take two zip ties and mount the valve by using one tie on e...

Страница 9: ...ur electrical wires and insert them one by one through the rubber grommet and then through the hole Pull all of the slack into the computer system control box Replace the grommet in the hole Next inst...

Страница 10: ...he computer system control box Replace the grommet in the hole Next install the single to double adapter Approach the compressor from the front The electrical plug and air valve are on the front Front...

Страница 11: ...onto either of the prongs atop the single to double adapter Next pull the two wires that lead to the valve on your right back to the hole in the box This prevents crossing the left and right side wir...

Страница 12: ...ox is not blocked from view Tie these wires using two or more zip ties Cut the excess from the ties secure wires to center of CGS box Replace the lid on the computer control system box and return the...

Страница 13: ...ed wait thirty seconds Slowly lower the air in the compressor to approximately 95 PSI and the compressor should start Open the valve by turning the handle counter clockwise to allow the air to reach t...

Страница 14: ...10 5508 Rev A Service Department 800 888 7009 14 2470 S Cherry Ave Fresno CA 93706 1 800 888 7009 Fax 559 256 8100 e mail info keiser com www keiser com...

Отзывы: