background image

Solenoid Valve Replacement for 1030/1031 Compressor

INTRODUCTION

KEISER CORPORATION has always taken pride in designing and engineering the
highest quality equipment on the market.   This means that you will receive years of low
maintenance and minimal repairs from every one of our machines.  Only the highest
quality products have the KEISER name on them.

WORD DEFINITIONS

SAFETY CAUTIONS and WARNINGS:

We've put a number of safety cautions in this book. We use the word 

Caution! 

to tell you

about things that could cause bodily injury to persons on or around the equipment if you
were to ignore the following instructions and the word 

Warning!

  to ensure the proper

installation of components and that the instructions are followed for the safety of the
users and for maximum machine life or the warranty is void.

HINTS:

We use the word 

Note!

  in this book to tell you about things that we recommend you

doing or things to be aware of before performing the instructions.  These notes were
placed in the manual to aid you during a certain procedure.

Warning!

Failure to follow the assembly or operation instructions as provided by this

manual or any other instructions pertaining to the assembly and/or

operation of KEISER equipment will result in voiding the warranty and

could lead to serious injury.

Tools Required: 

½ inch open-ended wrench
needle nose pliers
wire cutter

              standard size Phillips screwdriver

These items have been provided:  

8 zip ties

                 2 Allenair® valves

                                 

1 single to double adapter

Содержание 1031

Страница 1: ...o ensure the proper installation of components and that the instructions are followed for the safety of the users and for maximum machine life or the warranty is void HINTS We use the word Note in thi...

Страница 2: ...turned off it should be parallel to the compressor like this The Mac valve cannot be cleaned Therefore once faulty it must be replaced The Allenair valve functions well in this application and it can...

Страница 3: ...counter clockwise and remove the hose Unscrew nut counter clockwise Next cut the hose to the plastic elbow 3 8 inch from the end of the plastic elbow using the wire cutter cut tubing Repeat steps one...

Страница 4: ...mmet Inside the computer control system box cut all other zip ties holding the four wires Trace each of the wires from the valve to the circuit board There are two per valve four wires total The conne...

Страница 5: ...10 5508 Rev A Service Department 800 888 7009 5 1030 Circuit Board Diagrams Rev A B C Rev D Current...

Страница 6: ...alve installation 1 Adjust and mount new valve 2 Install single to double splitter and electrical wires 3 Secure and tie wires and replace lid 4 Test compressor 5 Note Keep two things in mind when you...

Страница 7: ...y mounting Use the inch open ended wrench to loosen the nut on the top of the new valve Loosen it just enough that you can rotate the red metal housing of the valve turn nut counter clockwise By adjus...

Страница 8: ...If you do not properly attach the hose the pressure from the compressed air will force the hose off the elbow push all the way down on elbow Take two zip ties and mount the valve by using one tie on e...

Страница 9: ...ur electrical wires and insert them one by one through the rubber grommet and then through the hole Pull all of the slack into the computer system control box Replace the grommet in the hole Next inst...

Страница 10: ...he computer system control box Replace the grommet in the hole Next install the single to double adapter Approach the compressor from the front The electrical plug and air valve are on the front Front...

Страница 11: ...onto either of the prongs atop the single to double adapter Next pull the two wires that lead to the valve on your right back to the hole in the box This prevents crossing the left and right side wir...

Страница 12: ...ox is not blocked from view Tie these wires using two or more zip ties Cut the excess from the ties secure wires to center of CGS box Replace the lid on the computer control system box and return the...

Страница 13: ...ed wait thirty seconds Slowly lower the air in the compressor to approximately 95 PSI and the compressor should start Open the valve by turning the handle counter clockwise to allow the air to reach t...

Страница 14: ...10 5508 Rev A Service Department 800 888 7009 14 2470 S Cherry Ave Fresno CA 93706 1 800 888 7009 Fax 559 256 8100 e mail info keiser com www keiser com...