08
AIR250 SEATED LEG CURL
|
OPERATION MANUAL
INSTALLATION AND PLACEMENT
TRAINING SPACE
Figure 4. Training Space for the 1221 & 1222 Air250 Seated Leg Curl
The equipment footprint is 58 inches x 45 inches (1,473 mm x 1,143 mm). The minimum recommended free space around the
equipment is 24 inches (610 mm) for the front and sides, and 6 inches (153 mm) for the rear.
Figure 3. How to Connect the Equipment to
the Keiser Air Supply
Note: Additional Free Space may be required to accommodate mobility device access.
No assembly required. Place the Air250 Seated Leg Curl on a flat, level surface. Make sure the base of the frame makes
full contact with the floor. If gaps are present, relocate the equipment to an even surface.
CONNECT THE EQUIPMENT TO THE KEISER AIR
SYSTEM
WARNING: Never connect equipment to an air
source capable of exceeding 120 psi / 8.27 bar.
Over pressurizing Keiser pneumatic equipment may
cause tubing to burst, breakage of equipment,
abnormal operation, or serious injury. Use only clean,
dry, regulated compressed air at the rated pressure
range of 100–120 psi / 6.89–8.27 bar.
1. Plug the Compressor into the appropriate power
source to power the Compressor ON
(allow the
Compressor to build up to a minimum of 100 psi /
6.89 bar; Keiser Compressor and Keiser Air System
not included, sold separately)
.
2. Connect the 1/4-inch Quick Disconnect (QD)
from the equipment into the Keiser Air Supply
(see Figure 3)
.
FREE AREA
FOOTPRINT
24 inches
(610 mm)
24 inches
(610 mm)
24 inches
(610 mm)
6 inches
(153 mm)
45 inches
(1,143 mm)
58 inches
(1,473 mm)
Keiser Air System
(floor or wall air outlet)
Direct-connect to
Keiser Small Air Compressor
Keiser
Large Air Compressor
Keiser
Small Air Compressor
1/4-inch QD