manualshive.com logo in svg
background image

18

AIR300 LEG EXTENSION PRO 

OPERATION MANUAL

The following routine maintenance is recommended annually or at the time batteries are replaced:

1.  Clean:

•  Wipe any accumulated dust around the Frame and the Belt System, including the Air Tanks and Cylinders, using 

a clean shop cloth.

2. 

Replace the Mufflers if discoloration is present.

•  Tool required: 11/16 inch Wrench or Adjustable Wrench.

3.  Replace the Air Filter if element is dirty (element turns a bright pink or red color):

• 

Tools required: Small Needle Nose Pliers, Cutter Tool (to cut off flared end of tubes).

4.  Visual inspection of Air Lines and Communication Wires:

•  Air Lines have no kinks, tears, or breaks; Communication Wires have no exposed wires or visible damage.

5.  Lubricate Cylinder Rods:

•  Wipe the Cylinder Rods clean and coat lightly with clean, SAE 30 motor oil, or with a silicon-based spray.

6.  Visual inspection of Belts and Linkage:

•  Belts are free of cracks, frayed edges, or otherwise excessive wear; bolts are tightened properly.

7.  Visual inspection of moving components:

•  Seat Lever functions properly and the adjustment mechanism engages properly. Check Exercise Arms are fully 

functional; all externally visible nuts and bolts are tightened properly.

1

2

3

4

5

6

7

Figure 12. Annual Routine Maintenance Illustration

Contact Keiser Customer Support for replacement part(s) order, or for any matters regarding the safe operation of your 
Air300 Leg Extension Pro (see back cover for contact information).

ANNUAL MAINTENANCE

WARNING: HIGH-PRESSURE AIR. 

DISCONNECT THE EQUIPMENT FROM 
THE AIR SUPPLY AND RELEASE ALL 
THE AIR IN THE EQUIPMENT (“— ” THUMB 
BUTTON) BEFORE PERFORMING ROUTINE 
MAINTENANCE. 

2

3

1

4

7

6

5

Содержание 001133BP

Страница 1: ...LEG EXTENSION PRO MODELS 001133BP 001133XP OPERATION MANUAL AIR300 STRENGTH CARDIO FUNCTIONAL...

Страница 2: ...INTENANCE 19 REGULATORY AND COMPLIANCE NOTICES 19_SAFETY NOTIFICATIONS 20_ELECTROMAGNETIC COMPATIBILITY EMC 20_US FCC COMPLIANCE STATEMENT 20_DISPOSAL 23 WARRANTY STATEMENT Keiser the Keiser logo and...

Страница 3: ...ay informed of safety notifications and for faster more accurate warranty service Scan the QR Code to the right to access the interactive online warranty registration form or visit https www keiser co...

Страница 4: ...p immediately Failure to follow these instructions could result in injury 15 Always maintain control of the Leg Cushions Exercise Arms duringexercise ThesuddenreleaseoftheExercise Arms during exercise...

Страница 5: ...tuation that if not avoided could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related IMPORTANT SAFETY INFORMATION Maintain and do not remove...

Страница 6: ...t arrhythmias at rest or aortic aneurysm If the patient is experiencing acute illness febrile condition i e fever or newly occurring pain this represents an absolute contraindication for physical stre...

Страница 7: ...Customer Support for service Maximum working pressure 125 psi 8 6 bar Maximum working temperature 104 F 40 C Minimum working temperature 32 F 0 C Maximum vessel capacity 68 in3 1 11 L per tank Model N...

Страница 8: ...the Compressor ON allow the Compressor to build up to a minimum of 100 psi 6 89 bar Keiser Compressor and Keiser Air System not included sold separately 2 Connect the 1 4 inch Quick Disconnect QD from...

Страница 9: ...Extension Pro Power Display Cylinders Seat Back Exercise Arms Processor Box Belts Seat Instruction Placard not shown Leg Cushions Seat Lever Increase Decrease Thumb Buttons Quick Disconnect QD with T...

Страница 10: ...deletes the current workout data from the eChip System Messages appear in the RESISTANCE window OFF low power consumption sleep mode Sleep mode occurs after 60 seconds of machine inactivity to help pr...

Страница 11: ...ata indicates no data was input to record Settings can only be changed immediately after the eChip is inserted and before your third rep After three reps are performed the setting cannot be changed un...

Страница 12: ...ed the Power Display remains blank see Battery Replacement procedure page 17 A Thumb Buttons and Display press Thumb Buttons to check for proper operation and the Display powers on B Upholstery Seat a...

Страница 13: ...he lever to move backward so your knees align with the machine pivot point 2 Grasp the Handgrips and adjust the resistance with the Thumb Buttons 1 2 Figure 9 How to Use the Air300 Leg Extension Pro F...

Страница 14: ...t the knee Move your feet up and at the same time to full knee extension move legs at the same level Keep your back supported by the Seat Back during movement ECCENTRIC PHASE DOWNWARD MOVEMENT Return...

Страница 15: ...nce high speed 80 90 of your maximum SET 2 Three repetitions Low resistance high speed 10 of your maximum SET 1 START TEST Press and hold both Thumb Buttons release when 6 r appears in the RESISTANCE...

Страница 16: ...Your Keiser Air Compressor not included with your Air300 Leg Extension Pro requires basic annual maintenance Contact Keiser Customer Support for Air Compressor operator manual or download at keiser co...

Страница 17: ...compartment insert the 2 new D batteries into the battery sleeve and install The Power Display will enter a brief test sequence youwillseeaseriesofnumbers flashing 4 Replace the Processor Box cover an...

Страница 18: ...cate Cylinder Rods Wipe the Cylinder Rods clean and coat lightly with clean SAE 30 motor oil or with a silicon based spray 6 Visual inspection of Belts and Linkage Belts are free of cracks frayed edge...

Страница 19: ...ociated with the disposal of waste products residues including disposal of the equipment itself at the end of its useful life The Air300 Leg Extension Pro contains electronic circuit assemblies 2 alka...

Страница 20: ...ELECTROMAGNETIC COMPATIBILITY EMC DISPOSAL This equipment contains electrical or electronic components alkaline batteries and a sealed lithium coin cell battery that must be disposed of properly to co...

Страница 21: ...21 AIR300 LEG EXTENSION PRO OPERATION MANUAL This page intentionally left blank...

Страница 22: ...22 AIR300 LEG EXTENSION PRO OPERATION MANUAL This page intentionally left blank...

Страница 23: ...day Friday 7 am to 5 30 pm PST or by email at service keiser com Customers outside the United States may obtain warranty information directly through a Keiser international distributor or dealer in th...

Страница 24: ...after reading this manual contact Keiser Customer Support 115506_C 1 559 256 8000 service keiser com keiser com support Telephone and Live Chat Monday Friday 7 am to 5 30 pm PST 24 Manufactured in the...

Отзывы: