![KEHUA TECH iStoragE Series Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/kehua-tech/istorage-series/istorage-series_user-manual_3914925086.webp)
A Technical Specifications
PV Energy Storage Inverter iStoragE Series
User Manual
78
All rights reserved ©Kehua Data Co., Ltd.
Model
Item
iStoragE B8
Operating temperature range
INV
:
-30~60
℃
(If the temperature higher than 45
℃
or lower than
-25
℃
, the inverter needs to decrease rated power to use)
BAT: -10
℃~
50
℃
(If the temperature higher than 45
℃
or lower than
-10
℃
, the inverter needs to decrease rated power to use)
Operating humidity range
0~95%
Cooling
Natural
Maximum operating altitude
3000m (
>
3000m derating)
Noise emission (typical)
<25db (A) @ 1m
Inverter design
Transformerless
Display
LED indicator
Communication
RS485 /WIFI/ /DRM (Australia)
AC terminal
Grid (max. 10mm²
) Back up (max. 6mm²
)
PV DC terminal
MC4 (max. 6 mm²
)
BAT terminal
MC4 (max. 10 mm²
)
The function
Whole machine
Update online
Specifications are subject to change without prior notice.