KL25164 -
Cannular Fully Automatic - Single Lane
Page
5
of
9
Last Updated 25/05/2023 14:27 PM
Common Faults and Troubleshooting
Fault
Possible Cause
Solution
No water in water pump
Loose or damaged seal
Inspect the seal and tighten /
replace
Leaking Keg during washing /
filling
Cylinder Loose
Inspect cylinder pressure
Keg not seated correctly
Fix keg position
Poor seal on keg spear
Adjust seal ring
Power Failure
Voltage exceeds the working
limit of PLC
Inspect input Power
Short circuit
Inspect Circuit
Indicator Lamp not working
Lamp is damaged
Replace Lamp
Residual beer in keg after
washing
Washing time is too short
Adjust time on PLC
Extractor tube damaged
Inspect tube for damage and
replace if required
Low Filling Speed
Retain-Valve pressure is too
high
Adjust pressure
Cannot Fill
Beer source pressure is too
low
Adjust pressure
PLC Time Parameter Adjustments
Follow the steps below to adjust any of the time parameters.
Below is the keg washing process page