KL25164 -
Cannular Fully Automatic - Single Lane
Page
3
of
9
Last Updated 25/05/2023 14:27 PM
Wiring
This unit will arrive unwired and it will require a licensed electrician to install three phase power
with grounding to provide power to the unit.
Specifications
Power
Capability
Washing Method
Suitable Keg Sizes
3 KW
30-40 kegs/hour
Inverted
5L
–
60L
Requirements
Air Source Pressure
Beer Source Pressure
CO
2
Pressure
Cylinder Valve Pressure
Air Blow Pressure
Filling Protection Pressure
0.5
–
0.6 MPa
0.15
–
0.25 MPa
0.2
–
0.3 MPa
0.5
–
0.6 MPa
0.3 MPa
0.05
–
0.10 MPa
Keg Washing Procedure
For commercial stainless steel kegs, the following washing procedure is followed:
Load the Keg
→ Keg Coupling → Drain → Water Rinse → Air Blow / Drain → Caustic Wash → Caustic
Recycle → Hot Water Wash → Drain → Sanitiser Wash → Sanitiser Recycle → Water Wash → Water
Recycle → Steam Sterilisation → Water Wash → Water Recycle → CO
2
Purge → CO
2
Pressurise
Keg Filling Procedure
For commercial stainless steel kegs, the following filling procedure is followed:
Load the Keg
→ Keg Coupling → CO
2
Pressurise → Filling → CO2 Blow of Filling Heads → Stop →
Unload Keg
(When filling PET kegs, make sure to close the needle valve of the cylinder)
CIP Procedure
Connect CIP Liquid to Beer Inlet
→ Install Washing Accessory → Start → Stop (Once CIP Time has
elapsed)
Pressure Adjustments and Air Pressure Regulator Maintenance
To adjust the set pressure on any of the pressure regulators follow the steps below:
1.
Pull up on the adjustment knob to unlock
2.
Turn the adjustment knob clockwise to increase output pressure and counter clockwise to
decrease output pressure
3.
Push the adjustment knob back in once at the desired output pressure to lock and set this
pressure.
Pour iso vg32 or equivalent lubricant into the air pressure lubrication reservoir periodically, inspect
the filter / water trap and drain off any water which has built up in the water trap