Connect to mains power and switch on 

Warning! The Speedster is made for either 110-120VAC or 220-240VAC power supply. Make sure 

that the power demands (see identity tag on front of machine) matches the local power 
supply before connecting the Speedster to the mains power. We cannot be held responsible 
for damages resulting from connecting the machine to incompatible mains power. 

 

Beware!

  

220-240 VAC Speedster

 has a maximum power consumption of 3100 Watts from your AC-outlet 

(max. power consumption limiter is disabled). This occurs when all three heating spirals and the pump 
are active simultaneously. At 230 Volts this is equivalent to approximately 13.5 amps. We therefore 
recommend that the machine has its own dedicated power circuit breaker. The max. power 
consumption limiter can be made active to reduce maximum power consumption to 2300 Watts, 10 
amps at 230 VAC; see leaflet that came with the Speedster. 

If you have ordered a 

110-120 VAC version of the Speedster

 (max. power consumption limiter is 

active; 2050 Watts, 17.8 amps at 115VAC), you must connect your power mains to a 110-120 VAC 
power outlet. The pump is fed from the Speedster and the pump-motor will be marked 110-120 VAC 
as well. Where we speak of 230 VAC in the rest of this manual, you should read 110-120 VAC. 

1.  Make sure that the mains switch is in the "OFF"-position. The mains switch is mounted on the 

identity tag on the front of the machine (see 

Figure W 1

, item 1). 

2.  The thinner electrical cable attached to the Speedster is the pump cable (see 

Figure I 3

)  and 

has a special type of connector. Attach the pump cable to the pump motor using the special 
connectors. 

3.  Attach the other cable to a 230 VAC earthed power outlet. If your Speedster came without a 

mains plug, it is advised to attach the blue wire to the neutral in your power outlet. (Although 
there is no difference in operational aspect, this makes it easier to check the electrics in case 
of a malfunction.) 

4.  Make sure that the Speedster rests on its feet.  
5.  Put the 3-way brewing lever on the right hand side of the machine (

Figure W 1

, item 4) in the 

lowest position (

Figure U 1

 

“pump active”). 

6.  Turn the mains switch on the machine to 

“ON”, the coffee boiler filling is continued.  

7.  Wait until water without air leaves the group. This procedure expels all air from the coffee 

boiler. A separate bleeding procedure is not needed.  

8.  After this move 

the lever in its high “off” position. The machine will now automatically fill its 

steam boiler.  

The displays of both temperature regulators (see 

Figure W 1

, items 2 & 17) will not show any value 

until a minimum water level in the steam boiler is reached. Filling procedure will continue till it reaches 
the maximum (operational) level. 
When the temperature in the steam boiler reaches boiling point some steam will escape through the 
anti-vacuum valve which makes a hissing or sputtering sound inside the machine. This will stop when 
the valve is shut by the increasing pressure inside the steam boiler. 

Adjust pump pressure 

The right hand side pressure gauge displays the pressure in the coffee boiler. The minimum value 
when the machine is at rest is the line pressure of the incoming tap water (as in other water taps in 
your house). Factory setting of the maximum pressure in the boiler is 11-13 bar. Above this value an 
expansion valve on the machine will open thus bleeding excessive pressure until the maximum value 
is no longer exceeded (this occurs when water with a lower temperature than the set value enters the 
coffee boiler, heats up and thus expands). 

Содержание Speedster 110-120VAC

Страница 1: ...CONTENTS Speedster page 1 110 120VAC version 220 240VAC version Installation and user manual Speedster Document ID Sup Sium Eng Date of issue August 21 2013 Revision date June 28 2017...

Страница 2: ...ove filter basket 17 Filter holder 17 Steam wand 17 Exterior 18 Back flush group 18 Replace group seal 19 Clean group dispersion plate 20 Maintenance 21 Recommended maintenance scheme 21 Maintenance R...

Страница 3: ...ay hot water toggle switch 6 Coffee boiler pressure gauge 7 Hot water valve 8 Hot water valve knob no operational function 9 Visible end of pre infusion piston 10 Group head 11 Shot timer display 12 S...

Страница 4: ...brew lever may lead to malfunction of the lever Parts included in standard shipment Accessories Stainless steel filter holder 2 cup spout Stainless steel filter holder 1 cup spout Water pump with ele...

Страница 5: ...rals will give your espresso a flat taste while also harming the boilers inside the machine As a rule of thumb the amount of total dissolved solids TDS in your water should be 100 150 mg l ppm We reco...

Страница 6: ...arly Not only changes in Alkalinity and Hardness of water but also temperature have dramatic effects on scale deposits and or aggressiveness of water on the machine thus no single water is optimal for...

Страница 7: ...ter treatment system see Figure I 1 Tighten with a 20 mm spanner Do not use excessive force 3 Attach the short high pressure hose to the outgoing side on the water treatment system Tighten with a 20 m...

Страница 8: ...exceeded yet 7 Open the tap and check the earlier made connections for leakage Tighten when needed but do not use excessive force In the meantime the front coffee boiler will start to fill with water...

Страница 9: ...other cable to a 230 VAC earthed power outlet If your Speedster came without a mains plug it is advised to attach the blue wire to the neutral in your power outlet Although there is no difference in...

Страница 10: ...asing the pump pressure further will not result in higher coffee boiler pressure Do not set the operational pressure higher than 9 5 bar since this will reduce the life span of valves etc in your Spee...