background image

KEEN PUMP COMPANY, INC. 

471 US Hwy 250 East, Ashland, OH  44805 

Phone:  419-207-9400        Fax:  419-207-8031 

 

Limited 3 – Year Warranty 

During the time periods and subject to the conditions hereinafter set forth, Keen Pump will repair or replace to 
the  original  user  or  consumer,  any  portion  of  your  new  Keen  product  which  proves  defective  due  to  defective 
materials  or  workmanship  of  Keen  Pump.    Contact  your  closest  authorized  Keen  Pump  representative  or 
distributor  for  warranty  service.    At  all  times,  Keen  Pump  shall  have  and  possess  the  sole  right  and  option  to 
determine  whether  to  repair  or  replace  defective  equipment,  parts  or  components.    Damage  caused  by  acts  of 
GOD or conditions beyond the control of Keen Pump is not covered by this warranty. 
 
WARRANTY PERIOD: 
36 months from date of manufacture. 
Start-up  reports  are  required  to  support  warranty  claims.    Warranty  effective  only  if  Keen  Pump  supplied  or 
authorized control panels are used.  Single phase pumps must utilize Keen Pump supplied start components. 
 
THIS WARRANTY WILL NOT APPLY: 

(1)

 

To defects or malfunctions resulting from failure to properly install, operate or maintained the product 
in accordance with printed instructions provided. 

(2)

 

To failures resulting from abuse, accident or negligence. 

(3)

 

To normal maintenance services and the parts used in conjunction with such service. 

(4)

 

To products which are not installed in accordance with applicable local codes, ordinances and good trade 
practices. 

(5)

 

The product is used for purposes other than for what is was designed and manufactured. 

(6)

 

If  3  phase  motors  are  installed  on  a  single  phase  power  supply  using  a  phase  converter  or  if  3  phase 
power is supplied by only two transformers, making an open Delta system. 

 
WARRANTY EXCLUSIONS: 
Keen Pump specifically disclaims the implied warranties of merchantability and fitness for a particular purpose 
after the termination of the warranty period set forth herein.  No warranties or representations at any time made 
by any representatives of Keen Pump shall vary or expand the provision hereof. 
 
LIABILITY LIMITATION: 
In  no  event  shall  Keen  Pump  be  liable  or  responsible  for  consequential,  incidental  or  special  damages  resulting 
from  or  related  in  any  manner  to  any  Keen  Pump  product  or  parts  thereof.    Personal  injury  and/or  property 
damage  may result from improper installation.  Keen Pump  disclaims all liability, including liability  under this 
warranty,  for  improper  installation.    Keen  Pump  recommends  following  the  instructions  in  the  installation 
manual.  When in doubt, consult a professional.  Some states do no allow the exclusion or limitation of incidental 
or consequential damages, so the above limitation or exclusion may not apply to you. 
 
LABOR, ETC., COSTS: 
Keen Pump shall in no event be responsible or liable for the cost of field labor or other charges incurred by any 
customer  in  removing  and/or  reaffixing  any  Keen  Pump  product,  part  or  component  thereof  or any  temporary 
pumping of other equipment. 
 
RETURNED OR REPLACED COMPONENTS: 
Any item to be replaced under this Warranty must be returned to Keen Pump, or such other place as Keen Pump 
may designate, freight prepaid. 
 
This warranty gives you specific legal rights and other rights which may vary from state to state. 
 
In the absence of suitable proof of this purchase date, the effective date of this warranty will be based upon the 
date of manufacture.  Example:  0105 = Month-Year = January, 2005. 

P/N O&M-KL RAILS

 

Содержание KL

Страница 1: ...07 8031 _______________________________________________________________________________ INSTALLATION AND SERVICE INSTRUCTIONS FOR KL GUIDE RAIL SYSTEM SUBMERSIBLE NON CLOG SEWAGE PUMPS _______________...

Страница 2: ...anual before operating pump Most accidents can be avoided by using COMMON SENSE KEEN PUMP is not responsible for losses injury or death resulting from a failure to observe these safety precautions mis...

Страница 3: ...There is no need to disconnect any piping or electrical connections to remove a pump for inspection or routine maintenance checks A typical system will operate on float control switches A bottom floa...

Страница 4: ...e box or main piping Install horizontal run extending through the wall of basin Secure vertical run to the vertical discharge piping using the appropriate method i e flange weld gasketed collar coupli...

Страница 5: ...ielectric gasket by others between dissimilar metals to avoid galvanic corrosion Allow excess float cable to loop over mounting bracket The sump level is controlled by Keen Pump float switch controls...

Страница 6: ...n by means of the chain or cable Disconnect the flexible conduit power and sensor cords from the control panel Pull the pump cord down through the pipe coupling while holding the cord on the underside...

Страница 7: ...ar the plugging 6 Discharge head may be too high Check elevation against design point of pump 7 Improper discharge flow Check for correct impeller size and proper voltage 8 Check for possible broken o...

Страница 8: ...using a phase converter or if 3 phase power is supplied by only two transformers making an open Delta system WARRANTY EXCLUSIONS Keen Pump specifically disclaims the implied warranties of merchantabil...

Отзывы: