Using
Weightanka
2
‐
21
of
28
Ensure that the roof is flat and that the slope is no more than 5
0
Ensure that the means of connection (lanyard etc.) is not in contact with any sharp
edges.
Ensure the surface of the roof is free from oil, algae, ice, snow and standing water.
Ensure the roof is structurally sound and shows no signs of damage
Ensure the Weightanka system shows no sign of damage or defects.
Ensure all screw threads are tightened firmly and the eyebolt torque using the tommy
bar provided.
Ensure the central attachment point of the Weightanka system is secure.
A warning notice should be placed on the central eyebolt so that no one disconnects the
personal protective equipment during use. This is the responsibility of the operator
Ensure you have observed all the instructions for use of the personal protective
equipment used in conjunction with the Weightanka system.
Exclusion zone
It is first necessary to establish an exclusion zone between WeightAnka and the roof edge, into
which no one should be allowed unless connected to WeightAnka (or other appropriate anchor, if
one exists). The exclusion zone should be designated by some form of marking or barrier, e.g.
KEEMARK demarcation system.
Always make the following checks!
Always Ensure!
Each inspection must be recorded in an inspection book!
You will find a sample page at the end of these operating instructions.