EXAMPLE A

Rear connection directly into a chimneybreast or 
a masonry chimney, e.g. a Heda Chimney.

Mark

 

the centre for the hole in the wall for the flue. 

Check that the height agrees with the stove's connec

-

tion height. Make a hole with a diameter of approx. 

180 mm using a drill and a chisel.

Install a pre-bushing of approx. Ø180 (not included) 

using heat-resistant mortar. The connecting pipe 

(not included) is measured and cut, so the end of the 

pipe ends at the level of the chimney's flue after it is 

installed.

When the stove is installed, connect the pipe to the 

stove's connection sleeve using a sealant and tightly 

caulk with oakum between the flue and the pre-bush

-

ing . 

NOTE! Bricking the pipe into the chimney is 

not allowed.

EXAMPLE B

Rear connection through a flammable wall

The connection is made in the same way as in ex

-

ample A, with the exception that the connecting pipe 

passes through a flammable wall.

The flammable wall therefore, must be furnished with 

a shaft with fire retardant lining (Masterboard, Minerit 

or equivalent) and be insulated with at least 100-mm-

thick fireproof insulation around the connection pipe. 

Thus, there must not be any flammable material closer 

than 100 mm from the flue.

When the outer diameter of the flue is Ø153 mm, the 

shaft must be at least 353 mm x 353 mm.

3. UNPACKING / DISMANTLING

The K800, broadly speaking, is supplied completely 

assembled, regardless of the model (815, 825 or 835). 

In the vast majority of cases, the parts of the stove 

models that can be assembled/disassembled are 

treated in the same way so, for this reason, we have 

chosen to use model 815 as an illustration, i.e. the 

cast iron model, as it is applicable to all models.

The stove can be moved in as delivered 

 but you 

should, however, take care with the top stone on mod

-

els 825 and 835, as it sits loosely. 

If you remove the assembly box prior to carrying it in, 

you should also remove the hearth plates as they are 

secured for transport using the box.

In connection with the above, or if you want to reduce 

the weight of the stove before moving it in, we de

-

scribe how you can in a few simple steps remove the 

parts involved. 

- 6 -

CHIMNEY

CHIMNEY

CUT

OFF

CUT

OFF

BUSHING

BUSHING

CONNECTING PIPE

CONCRETE WALL

FIREPROOF INSULATION 100 MM

 INSULATION 

SHAFT FROM FIRE-

RETARDENT LINING

 WALL

Содержание K800 Series

Страница 1: ...K800 Installation instructions Care and firing instructions ...

Страница 2: ... Floor plate Outdoor air supply Flue Chimney connections PREPARATIONS 5 8 Flue connections for rear and top installation Floor plate and outdoor air connection Unpacking INSTALLATION INSTRUCTIONS 9 11 CARE FIRING INSTRUCTIONS 12 14 TECHNICAL SPECIFICATION 15 Dimensions and performance Dimension drawings CERTIFICATES 15 2 ...

Страница 3: ...in accordance with the documents that form the basis for the respective certificates and their associated requirements for production inspections IMPORTANT POINTS Contact the Planning and Building Committee in your municipality concerning the building notice It is also recommended that you contact a certified chimney sweep prior to installation NOTE Read through all of the installation instruction...

Страница 4: ...an use Keddy s own floor plate or floor glass These are installed after completing the installation of the stove OUTDOOR AIR SUPPLY The combustion of wood requires air supply air The K800 can be provided with an external air supply which is recommended for properties with mechani cal ventilation see also under the heading Good to know on page 13 A sheet metal drum is used for drawing an outdoor ai...

Страница 5: ... flue Alternative 1 Rear installation Alternative 2 Top installation Height from the floor to the centre of the flue at the rear 920 mm Height from the floor to the height of the connection top 1060 mm Note If you install Keddy s floor glass the di mensions above must be extended by 6 mm i e they become 926 and 1066 mm Outer diam of the rear top sleeve connection Ø150 For so called top connection ...

Страница 6: ...insulated with at least 100 mm thick fireproof insulation around the connection pipe Thus there must not be any flammable material closer than 100 mm from the flue When the outer diameter of the flue is Ø153 mm the shaft must be at least 353 mm x 353 mm 3 UNPACKING DISMANTLING The K800 broadly speaking is supplied completely assembled regardless of the model 815 825 or 835 In the vast majority of ...

Страница 7: ...nal since the lock can be operated using the glove by press ing directly on the lock hasp on the lower right of the door NOTE To close the door push it closed without lifting the lock hasp 2 Remove the log guard the grate and the ash pan 3 Remove the hearth plates Begin by pressing the smoke shelf upwards so you can remove one of the side plates After this remove in order the smoke shelf the secon...

Страница 8: ...om falling on the floor Please note that the lower part of the cast iron panel are located with two heels that fit into two holes in the stove body If the panel is made of stone concrete there a groove that locates onto two elevations in the stove body You have now removed all of the necessary parts and can unscrew the stove and move it into the house NOTE Because the stove is heavy and is also eq...

Страница 9: ... fit into the pre punched holes in the four corners of the plate If outdoor air is to be connected from below the cover plate on the bottom plate has to be removed and the 100 63 mm reduction piece installed before the stove is put into place 2 If the stove is to have a rear connection the back plate must be removed Loosen the two screws in the top corners Incline the back plate so it can be lifte...

Страница 10: ... the stove on in order to protect the floor while manoeuvring it into position 4 Connect the outdoor air connection if any When the connection is from the rear the insulation sock needs to be shortened and then threaded on the hose inside the base Press the hose firmly onto the stove s supply air terminal 5 For a rear connected stove you now connect the prepared flue to the back connection sleeve ...

Страница 11: ...comes fully insulated approx 60 mm of insulation For additional information about the installation of the chimney please refer to the installation instructions for the brand of chimney you have selected 8 Install the hearth plates the grate and the ash pan For illustration see points 2 and 4 on page 7 9 Assemble the base glass and connect the electric cable to the socket on the rear base plate You...

Страница 12: ...r both people and the environment FIRING IN AUTOMATIC MODE The K800 is equipped with a feature that ensures that the firing is as safe and environmentally friendly as possible A heat probe which detects the outgo ing flue gas temperature is positioned in the top of the stove The probe sends a signal to a control unit which then automatically controls a damper to ensure the optimum combustion of th...

Страница 13: ...s new a certain smell can arise This is caused by the paint and anti corrosion agent hardening Ensure good airing and the smell will disappear after the stove has been fired a couple of times Open a window near the stove if there is negative pressure in the house Leave the window open until the fire starts to burn normally Light the fire in the fol lowing way Automatic mode 1 Open the door Put in ...

Страница 14: ...n relation to the ad ditional oxygen supply and wait before adding more wood until the old fire has burnt out REMOVAL OF SOOT AND MAINTENANCE Soot must be removed at least once per season The soot from the chimney and the connections should be removed by a chimney sweep The smoke shelf and the vertical hearth plates must be removed during sweeping You will find instructions on how this is done und...

Страница 15: ...dth 392 5 mm Depth 400 mm Weight K815 125 kg Weight K825 835 135 kg Height centre rear connection 920 mm If installed with floor glass 926 mm Height top connection 1060 mm Outer dimensions connection sleeve Ø150 mm Useful efficiency 73 Rated output 6 7 kW License number 378 016 ...

Страница 16: ...www keddy se Rev 5 26 05 2011 ...

Отзывы: