Disposal

8.1 

Disposal of the module

CAUTION

Please observe the regulations regarding disposal of electric appliances and
electronic devices!

The symbol with the crossed-out waste container means that electrical
and electronic devices including their accessories must not be disposed
of in the household garbage.

The materials are recyclable in accordance with their labeling. You can
make an important contribution to protecting our environment by reusing,
renewing and recycling materials and old appliances.

FM 280/A

Disposal

© KEBA 2011

Project engineering manual V1.02

19

Содержание Kemro FM 280/A

Страница 1: ...Kemro FM 280 A SERCOS II Interface Module Project engineering manual V1 02 Translation of the original instructions ...

Страница 2: ...10 E Mail keba keba com D KEBA GmbH Automation Leonhard Weiss Straße 40 D 73037 Göppingen Tel 49 7161 9741 0 Fax 49 7161 9741 40 E Mail keba keba com US KEBA Corp 100 West Big Beaver Road Troy MI 48084 US Tel 1 248 526 0561 Fax 1 248 526 0562 E Mail usa keba com CN Beijing Austrian KEBA Science and Technology Development Ltd Room B516 Nan Xin Cang Tower A22 Dong Si Shi Tiao Dong Cheng District Bei...

Страница 3: ...anged by 1 00 11 2007 newly created meis 1 01 08 2010 Declaration of con formity Savety notes updated hasl 1 02 08 2011 Introduction Hint not for end customers added various minor up dates fstl FM 280 A Record of Revision KEBA 2011 Project engineering manual V1 02 3 ...

Страница 4: ......

Страница 5: ...ns and wiring 15 5 1 SERCOS Interface 15 5 1 1 Connection example 15 5 1 2 Cable and connector specification 16 5 1 3 Cable length 16 5 2 EMC and wiring guidelines 16 6 Configuration 17 6 1 Setting the K Bus address 17 7 Operating behavior 18 7 1 Start up after Power On 18 8 Disposal 19 8 1 Disposal of the module 19 9 Technical data 20 9 1 In general 20 9 2 Environmental conditions 20 9 3 SERCOS I...

Страница 6: ... 10 2 4 Environmental and surrounding conditions 21 10 3 Standards for the American market 21 10 3 1 UL test for industrial control equipment 21 11 Declaration of conformity 22 Table of Contents FM 280 A KEBA 2011 Project engineering manual V1 02 6 ...

Страница 7: ...ngineering degree or corresponding professional experience Knowledge in working mode of a PLC safety regulations the application Operator Basic technical training Vocational high school engineering degree or corresponding professional experience Knowledge in safety regulations working mode of machine or plant principal functions of the application system analysis and troubleshooting setting option...

Страница 8: ...ons relating to the intended use are properly observed 1 4 Notes on this document This manual is integral part of the product It is to be retained over the entire life cycle of the product and should be forwarded to any subsequent owners or users of the product 1 4 1 Contents of the document Description of the FM 280 A Description of wiring including EMC guidelines Technical data 1 5 Documentation...

Страница 9: ...get group DE 1000868 EN 1000869 System manual Kemro automation system Project engineer Electrician Programmer Commissioning foreman Service technician FM 280 A Introduction KEBA 2011 Project engineering manual V1 02 9 ...

Страница 10: ...jury or slight bodily injury CAUTION CAUTION used without the safety alert symbol indicates a potentially haz ardous situation which if not avoided may result in damage to property This symbol reminds you of the possible consequences of touching elec trostatically sensitive components Information Useful practical tips and information on the use of equipment are identified by the Information symbol...

Страница 11: ...s to irreparable dam age Turn off the power supply before inserting or removing the module Other wise the module can be destroyed or undefined signal states can lead to damage of the control system FM 280 A Safety notes KEBA 2011 Project engineering manual V1 02 11 ...

Страница 12: ...0 A per K Bus row The FM 280 A may only be connected with CP Modules not with bus link modules 3 1 General functionality of SERCOS The SERCOS module is activated via K Bus on the CPU module The gener ated SERCOS frames are available for members on the optic waveguide interface max members 254 Further information www sercos de Description of the module FM 280 A KEBA 2011 Project engineering manual ...

Страница 13: ... control or coordination of machine move ments Optical waveguide technology The data are transmitted via optic waveguide technology glass or plastic fiber cables which offers the following advantages Simple wiring Interference immune and fast data transfer Switchable data rate Two data rates can be set 2 MBit s 4 MBit s FM 280 A Description of the module KEBA 2011 Project engineering manual V1 02 ...

Страница 14: ...ror LED is on Ring circuit not closed receiver signal interference or ring not configured 4 2 SERCOS LEDs TX and RX Color Meaning Comment Yellow TX Transmit LED is on At transmission activity Green RX Receive LED is on On receipt of frames Operating elements and displays FM 280 A KEBA 2011 Project engineering manual V1 02 14 ...

Страница 15: ...optical waveguide will then connect with the receiver of the next bus participant The optical waveguide must then close the circuit from the transmitter of the last bus participant to the receiver of the FM 280 A See also the following graphic Fig 5 1 Connection example FM 280 A A Drive E Receiver connection S Transmitter connection Information It is only possible to use one FM 280 A per K Bus row...

Страница 16: ... m Information We recommend using finished and standardized optical waveguides from specialist suppliers Please do not hesitate to ask your KEBA contact partner for further information 5 2 EMC and wiring guidelines Pay attention from the outset to careful wiring and shielding Further information See system manual Connections and wiring FM 280 A KEBA 2011 Project engineering manual V1 02 16 ...

Страница 17: ...mponents and devices Configuration data is created by included configuration tools or by editing con figuration files For further information to the configuration see the documentation of the in cluded configuration tool 6 1 Setting the K Bus address Since only one FM 280 A may be added to a CPU module no address setting of the module address is required FM 280 A Configuration KEBA 2011 Project en...

Страница 18: ...7 Operating behavior 7 1 Start up after Power On The module is passive and is configured and activated through the HOST Operating behavior FM 280 A KEBA 2011 Project engineering manual V1 02 18 ...

Страница 19: ...ainer means that electrical and electronic devices including their accessories must not be disposed of in the household garbage The materials are recyclable in accordance with their labeling You can make an important contribution to protecting our environment by reusing renewing and recycling materials and old appliances FM 280 A Disposal KEBA 2011 Project engineering manual V1 02 19 ...

Страница 20: ...f air 10 to 95 non condensing Vibration resistance according to EN 61131 2 2007 Shock resistance according to EN 61131 2 2007 9 3 SERCOS II Interface Data transmission rate 2 MBit s and 4 MBit s configurable per soft ware Max cable length optical waveguide 50 m with plastic fibers 250 m with glass fiber Transmitting Receiving display Transmission LED receival LED status LED Connection Optical wave...

Страница 21: ...tion This product was developed for the use in industrial areas and can cause radio interference when used in residential areas 10 2 2 EMC guideline EN 61131 2 2007 Programmable controllers Part 2 10 2 3 Electrical safety and fire protection EN 61131 2 2007 Programmable controllers Part 2 10 2 4 Environmental and surrounding conditions EN 61131 2 2007 Programmable controllers Part 2 10 3 Standards...

Страница 22: ...11 Declaration of conformity Declaration of conformity FM 280 A KEBA 2011 Project engineering manual V1 02 22 ...

Отзывы: