The measuring aid has now been installed on the device, and the manual
measurement can be executed.
Carrying out the measurement
For the manual measurement, proceed as follows:
1) Attach the measuring aid to the device.
2) Switch the device on by pressing the operating button.
3) Navigate to the
Manual
menu item by pressing and holding the operating
button.
4) Place the device close to the workpiece so that the measuring aid
touches the bending edge.
5) Start the measurement (switch on the laser) by pressing the operating
button once.
6) Position the device so that the laser beam can hit both legs of the work-
piece at an angle of 90° without being obstructed.
7) Hold the device still until the measurement is complete and the laser
switches off automatically.
The measured result can be read off the display after the measurement has
ended. The laser is automatically switched off after the measurement.
Information
●
The measurement can be terminated early by pressing the operating
button briefly. After 40 seconds without a measurement result, the mea-
surement is ended automatically.
●
If the laser beam does not hit both legs at an angle of 90°, an alternative
position must be selected for the measurement.
Continuous measurement
In the continuous measurement, a measurement is carried out continuously
and the measured angle is displayed immediately. In this mode, long sheet
metal parts can be measured along the entire bending edge, for example. In
order to start the continuous measurement, proceed as follows:
1) Press and hold the operating button until
appears on the display.
2) Carry out the measurement.
The measurement can be terminated by pressing the operating button 2x
briefly.