UDP commands
9 / 12
"Enable user" = Enable condition via UDP.
"Max curr"
= Current preset value via Control pilot in milliampere.
"Max curr %"
= Current preset value via Control pilot in 0,1% of the PWM value
"Curr HW"
= Highest possible charging current of the charging connection.
Contains device maximum, DIP-switch setting, cable coding and
temperature reduction.
"Curr user"
= Current preset value of the user via UDP; Default = 63000mA.
"Curr FS"
= Current preset value for the Failsafe function.
"Tmo FS"
= Communication timeout before triggering the Failsafe function.
"Curr timer"
= Shows the current preset value of currtime.
"Tmo CT"
= Shows the remaining time until the current value is accepted.
"Setenergy”
= Shows the set energy limit.
"Output"
= State of the output X2.
"Input"
= State of the potential free Enable input X1.
When using the input, please pay attention to the information
in the installation manual.
"Serial"
= Serial number
"Sec"
= Current system clock since restart of the charging station.
UDP command:
report 3
Reply:
{
"ID": "3",
"U1": 230,
"U2": 230,
"U3": 230,
"I1": 99999,
"I2": 99999,
"I3": 99999,
"P": 99999999,
"PF": 1000,
"E pres": 999999,
"E total": 9999999999,
"Serial": "15017355",
"Sec": 4294967296,
}
Description:
"ID"
= ID of the retrieved report.
"U1"|"U2"|"U3"| = Current voltage in V.
"I1"|"I2"|"I3"|
= Current current value of the 3 phases in mA.
"P"
= Current power in mW (Real Power).
"PF"
= Power factor in 0,1% (cosphi)
"E pres"
= Power consumption of the current loading session in 0,1Wh;
Reset with new loading session (state = 2).
"total"
= Total power consumption (persistent) without current loading
session 0,1Wh; Is summed up after each completed charging
session (state = 0).
"Serial"
= Serial number